eDAQ termékek
Az alábbi táblázatban eDAQ termékeket kereshet, melyekre a Szkarabeusztól egyéni árajánlatot tud kérni.
-
CikkszámNévLeírásRészletekHozzáadás
-
EA010GP Analog module for ER825 PBAResearch SystemsEA010 is a General Purpose module required to connect DC signal of +/-10V to an ER825 system. It provides an 8 Pin Input connector which can control analog Isopods. Gain, filter settings and offset are all software controlled. Up to 8 EA010 couplers can be fitted in one ER825 system. This req the pod adapter cable
-
EA025C4D MODULE PBAResearch SystemsEA025 is a C4D head stage module required to connect a C4D head stage to an ER825 system. It provides push pull excitation frequencies (10 kHz to 2MHz) and amplitudes (100mV to 20Vpp). Gain, filter settings and offset are all software controlled. In addition it identifies head stage type and settings on future head stages fitted with flash memory. Up to 8 EA025 couplers can be fitted in one ER825 system.
-
EA120C4D AmpAmplifiers & PotentiostatsEA120 Contactless Capacitively Coupled Conductivity Detector (C4D) amplifier, suitable for all eDAQ C4D Head stages. A wide range of excitation frequencies (100 kHz to 2MHz) and amplitudes (.2 to 20Vpp) can be applied to the detector under computer control thus providing a wide dynamic range of conductivity measurements. Background conductivity can be offset to provide better resolution peak data. The C4D Amp connects to any e-corder system which provides power and control and supported by PowerChrom or Chart software. Head stage must be ordered separately
-
EA163Potentiostat EA163Amplifiers & PotentiostatsThe EA163 Potentiostat MkII is a software controlled 3-electrode potentiostat/Galvanostat for use in general electrochemistry applications. ZRA and Hi Z modes are also available. Current ranges from 20 nA to 100 mA full scale with 16 bit resolution and 12 V compliance. Includes iR compensation. It replaces the EA161 and has extended frequency response to 100 kHz for use with the Z100 EIS system. It supports all EChem methods. Supplied with all necessary cables.
-
EA164QuadStatAmplifiers & PotentiostatsEA164 QuadStat contains four software controlled potentiostat channels for use in a number of electrochemistry applications. Current ranges from 10mA to 200pA full scale at up to Ă_x0082_Âą10 V with 12V compliance. It supports all EChem methods (on a single channel only). Supplied with all necessary cables.
-
EA165Potentiostat EA165Amplifiers & PotentiostatsThe EA165 Potentiostat MkII is a software controlled 3/4-electrode potentiostat/Galvanostat for use in general electrochemistry applications. ZRA and Hi Z modes are also available. Current ranges from 20 nA to 200 mA full scale with 16 bit resolution and 12 V compliance. Includes iR compensation. It replaces the EA163 and has extended frequency response to 100 kHz for use with the Z100 EIS system. It supports all EChem methods. Supplied with all necessary cables.
-
EA167Dual Reference AdaptorAmplifiers & PotentiostatsThe ER167 Dual Reference Adapter is connected to the reference electrode lead of a three-electrode potentiostat (e.g. EA160, EA161, EA163, ER466) so that two reference electrodes can be used. Typically used for trans-membrane electrochemistry experiments, or studies across the interface of two immiscible liquids, where a 4-electrode potentiostat is required.The Unit can also be used as a Stand Alone Hi Z Differential amp
-
EA362Dual PicoStat EA362Amplifiers & PotentiostatsThe EA362 Dual Picostat is a galvanically isolated, software controlled high sensitivity potentiostat featuring: single 3-electrode potentiostat mode (RE, AE, and WE) dual 3-electrode mode (two each of RE, AE and WE) bipotentiostat mode (RE, WE, and two WE) 4-electrode mode (two RE and two WE) for use in electrochemistry or neurophysiology. Current ranges from 20 pA to 100 uA full scale and 12 V compliance. It supports all EChem methods. Supplied with all necessary cables and a mains powered 12 volt power pack.
-
EA910Set of 12 open top caps with silicon liner for V-vialsAccessoriesSet of 12 open top caps with silicon liner for V-vials
-
EC001-4BNC to BNC Cables (1 m)Cables and ConnectorsPack of Four, fully moulded BNC to BNC cable. Length: 1m
-
EC002Cable, DB9M to DB9F - 350mm longCables and ConnectorsA 9 pin D-type male to 9 pin D-type female cable, supplied with all eDAQ Amps. For connecting the I2C control port of an eDAQ Amp to the I2C port of an e-corder. It can also be used for making a 'daisy chain' of multiple Amps.
-
EC004Cable, BNC to 4 mm Banana PlugCables and ConnectorsBNC to dual 4 mm Banana Plug Cable (3m long).
-
EC005Cable, BNC to BNC 2m)Cables and ConnectorsFully moulded BNC to BNC cable, 1m long. For connecting eDAQ Amps or other devices with a BNC output to an e-corder unit.
-
EC006Cable, US Mains PowerCables and ConnectorsCable, US Mains Power1.8M IEC
-
EC007Cable, Set of two cables, BNC to Alligator Clip (Red, Green)Cables and ConnectorsPair of cables, BNC to Alligator Clip. Yellow / Black. Used with ER167 Dual reference Adapter.
-
EC008BNC to Pair of Alligator ClipsCables and ConnectorsCable, BNC to pair of Alligator Clips 750 mm Long
-
EC009BNC Male to 4 mm Banana Plug AdapterCables and ConnectorsBNC to 4 mm Banana Plug adapter used to connect individual conductors to a BNC connection.
-
EC010BNC T pieceCables and ConnectorsBNC T-piece for splitting a signal.
-
EC011Cable, 4mm Banana Plug to 4mm Banana Plug, Green 700mm longCables and Connectors4 mm to 4 mm green banana plug non-stackable cable 700 mm long. Used to connect two system grounds.
-
EC012Cable, 4mm Banana Plug to Alligator with 2mm Stackable PlugsCables and ConnectorsGreen 4 mm plug to 2 mm Green Plug terminated with a Green Alligator clip - 750 mm Long. Used to ground transducer shield.
-
EC013Cable, European Mains PowerCables and ConnectorsCable, European Mains Power1.8M IEC
-
EC014Cable, 4mm Banana Plug to 2mm Plug, Alligator Clip, RED (PACK of 4)Cables and ConnectorsPACK of 4 cables. Each cable consists of a RED 4 mm plug at one end of a 750 mm long thin flexible cable and a 2 mm stackable RED plug terminated with a RED Alligator clip.
-
EC015Cable, Chip holder Ground Cable, GreenCables and ConnectorsGreen 4mm plug to 2mm Green Plug - 750mm Long.
-
EC016Cable, BNC to BNC (6 m)Cables and ConnectorsBNC to BNC cable, length 6m.
-
EC017Cable, Stackable 4mm Banana Plug to Stackable 4mm Banana Plug, Green 450mm longCables and Connectors4 mm to 4 mm green banana plug non-stackable cable 450 mm long
-
EC018Cable, Stackable 4mm Banana Plug to Stackable 4mm Banana Plug, Green 1000mm longCables and Connectors4 mm to 4 mm green banana plug non-stackable cable 1 m long
-
EC019Cable, Australian Mains PowerCables and ConnectorsCable, Australian Mains Power1.8M IEC
-
EC020C4D 3 Ion StandardAccessoriesEC20 is a set of 2 sealed sterilized ampoules containing a 0.5M acetic acid buffer and a 1mM solution of each of lithium, sodium, potassium, chloride, nitrate, and sulphate ions in deionised water. Individual Test certificates provided by Absolute Standards Inc.
-
EC023PACK OF O RINGs FOR UCHIP HOLDERAccessories3MM 1MM O RING PACK OF 10 (For ET225 UCHIP HOLDER)
-
EC024PACK OF O RINGs FOR ET014Accessories#001 Qty 2#003 Qty1#004 Qty 1#006 Qty 1
-
EC02520 POS Instrument Connection Port Adapter PackAccessoriesPheonix Contact Mini Combican Instrument Connection Port Adapter. Green Plug component, nominal current: 8 A, rated voltage: 160 V, pitch: 3.5 mm, no. of positions: 20, type of connection: Screw connection. Used in QuadStat, PowerPhrom.and other eDAQ products.
-
EC02520 POS Instrument Connection Port Adapter PackCables and ConnectorsPheonix Contact Mini Combican Instrument Connection Port Adapter. Green Plug component, nominal current: 8 A, rated voltage: 160 V, pitch: 3.5 mm, no. of positions: 20, type of connection: Screw connection. Used in QuadStat, PowerPhrom.and other eDAQ products.
-
EC026Cable, UK Mains PowerCables and ConnectorsCable, UK Mains Power1.8M IEC
-
EC028Cable adapter 8 Way Lemo to 8 Way Female DIN.Cables and ConnectorsLemo to DIN Adapter Short adapter cable connecting the EA010 input to e corder 8 way DIN socket.suitable for pod connections and General purpose use
-
EC032Cable, DB9M to DB9F - 1.8m longCables and ConnectorsA 9 pin D-type male to 9 pin D-type female cable, supplied with all eDAQ Amps. For connecting the I2C control port of an eDAQ Amp to the I2C port of an e-corder. It can also be used for making a 'daisy chain' of multiple Amps.
-
EC051Cable, BNC to Alligator with 2mm stackable plugs, GREEN, (PACK of 4)Cables and ConnectorsPACK of 4 cables. Each cable consists of a BNC plug at one end of a 750 mm long thin coax cable and a 2 mm stackable Green plug terminated with a Green Alligator clip. Used with EA164 QuadStat.
-
EC052Cable, BNC to Alligator,with 2mm stackable plugs, YELLOW, (PACK of 4)Cables and ConnectorsPACK of 4 cables. Each cable consists of a BNC plug at one end of a 750 mm long thin coax cable and a 2 mm stackable yellow plug terminated with a yellow Alligator clip. Used with EA164 QuadStat.
-
EC053Cable, BNC to Alligator,with 2mm stackable plugs, BLUE ( PACK OF 4)Cables and ConnectorsPACK of 4 cables. Each cable consists of a BNC plug at one end of a 750 mm long thin coax cable and a 2 mm stackable blue plug terminated with a blue Alligator clip.
-
EC054Cable, BNC to Alligator,with 2mm stackable plugs, BLUE & Yellow ( PACK OF 2)Cables and ConnectorsBNC to stackable 2mm terminal, 2 mm terminals fitted with blue and yallow alligator clips.
-
EC060Cable, BNC to Tinned EndsCables and ConnectorsEC060 is BNC to bare tinned ends cable 750 mm long
-
EC071Cable, Trigger cable- DB9 male to tinned ends EC071Cables and ConnectorsAgilent 7100 trigger cable consisting of a DB9M to Tinned end cable 750 mm long. This cable is also available to connect to ER125 or ER225 systems Trigger. Available to special order only. Also available as a EC072 DB9 to BNC for connection to an e-corder trigger.
-
EC072Cable, Agilent 7100 Trigger cable EC072- DB9 male to BNCCables and ConnectorsAgilent 7100 trigger cable consisting of a DB9M to BNC cable 750 mm long for connecting a trigger to an e-corder, Available to special order only. Also available as a EC071 DB9 to Tinned ends for connection to an ER125 or ER225 Trigger.
-
EC073Cable, ER815/825 Trigger cable- DB9 Female to BNCCables and ConnectorsCable, ER815/825 Trigger cable consisting of a DB9F to BNC cable 750 mm long for connecting a ER815/825.
-
EC074Cable, Trigger cable- DB9 female to tinned ends EC074Cables and ConnectorsTrigger cable consisting of a DB9F to Tinned end cable 750 mm long. Special modification required as per BS instructions. This cable is also available to connect to ER815 or ER825 systems Trigger. Optional trigger cable to be purchased separately with ER815 and ER825 unit.customers options including EC071/EC072/EC073
-
EC091Foot SwitchAccessoriesThe foot switch is used as a triggering device. The switch has a normally open contact and when depressed gives contact a closure. It is connected to the trigger input of an e-corder.
-
EC092Push Button SwitchAccessoriesThe Push Button switch is used as a triggering device. The switch has a normally open contact and when depressed provides a contact closure. It is connected to the trigger input of an e-corder.
-
EC1208Headstage Adapter assembly with 8 pin DINCables and ConnectorsHeadstage Adapter with DIN 8 Way
-
EC1210Headstage Adapter assembly with 10 way LemoCables and ConnectorsHeadstage Adapter with Lemo 10 Way
-
EC161Cable, Electrode Cable for EA160 PotentiostatsCables and ConnectorsInput cable. Provides shielded connection between EA160 and electrochemical cell. 8 Pin DIN cable to 3 alligator clips. Length 750 mm
-
EC162Cable, Electrode Cable for PotentiostatsCables and ConnectorsInput cable. Provides shielded connection between electrode and the EA161 and EA163 Potentiostats, EA162 Picostat, ER466 Potentiostat, and EA362 Dual Picostat. 6 Pin Lemo to 3 removable alligator clips. Length 850 mm
-
EC163Cable, Electrode Cable for Potentiostats-LongCables and ConnectorsInput cable. Provides shielded connection between electrode and the EA161 and EA163 Potentiostats, EA162 Picostat, ER466 Potentiostat, and EA362 Dual Picostat. 6 Pin Lemo to 3 removable alligator clips. Length 1500 mm
-
EC167Cable, Electrode Cable for High Current PotentiostatsCables and ConnectorsInput cable. Provides shielded connection between electrode and the ER467 / EA165. 8 Pin Lemo to 5 removable alligator clips -Red Yellow green black and blue. Length 850 mm
-
EC201Cable,Trigger twin cable with tinned endsCables and ConnectorsEC201 is a bare wire to bare wire cable 750 mm long. Use in some trigger applications
-
EC230Cable. EC230-4 HV cable setCables and ConnectorsA set of four different color cables 750 mm long, SHV connector at one end to bare platinum wire termination at the other, to facilitate connection of the ER430 HV Sequencer to an undefined user device. The user must provide suitable high voltage protection and be responsible for safe connections.
-
EC255Cable, Differential Pod InputCables and ConnectorsCable consisting of an 8 pin DIN/Pod connector to three alligator clips. Suitable for connecting a differential or low level signal to the differential input of an e-corder .
-
EC299Cable, MicroNit head cableCables and ConnectorsHDMI to Din8 cable assembly.
-
EC400Front Panel,Plastic, Small Chassis, Small recess UnpaintedCables and ConnectorsNone
-
EC401Potentiostat Cable kit for EA163 - EA466 - EA162 - EA362Cables and ConnectorsEC012 4 mm to 2 mm GREEN cable with Alligator clip EC162 Electrode Cable for Potentiostats - 850mm Long with Alligator clips EC409 3-way BNC to BNC cable. Used with Potentiostat & Picostat
-
EC402QuadStat cable KitCables and ConnectorsEC012 4 mm to 2 mm GREEN cable with Alligator clip EC014 Cable, 4 mm Plug to 2 mm stackable plug with RED Alligator clip, (PACK of 4) EC025 20 POS Instrument Connection Port Adapter Pack EC051 Cable, BNC to Alligator, with 2 mm stackable GREEN plug, (PACK of 4) EC052 Cable, BNC to Alligator, with 2 mm stackable YELLOW plug, (PACK of 4) EC060 Cable, BNC to Tinned ends EC408 4-way BNC to bare wires cable. Length 1.2 m EC408 4-way BNC to bare wires cable. Length 1.2 m
-
EC405Cable, USB Cable 2m Moulded Type A-BCables and ConnectorsUSB Cable (Type AB) suitable for connecting an e-corder or PowerChrom to a computer.
-
EC406USB miniB Cable used by USB isoPodsCables and ConnectorsUSB Cable (Type A to miniB) suitable for connecting a USB isoPod to a computer or USB hub
-
EC4084 Way BNC to Tinned endsCables and Connectors4-way BNC to bare wires cable. Length 1.2 m. Two of these cables are supplied with a Quadstat unit
-
EC409Cable, BNC to BNC Cable 3 way Colour coded-1000mm longAccessories3-way BNC to BNC cable. Length 1.5 m. Supplied with EA161 and EA163 Potentiostats and EA162 Picostat.
-
EC409Cable, BNC to BNC Cable 3 way Colour coded-1000mm longCables and Connectors3-way BNC to BNC cable. Length 1.5 m. Supplied with EA161 and EA163 Potentiostats and EA162 Picostat.
-
EC410Reed relay Interlock cableCables and ConnectorsCable with BNC and reed relay interlock
-
EC412Black and Red Alligator Clips (Pack of 5 each)Cables and ConnectorsEC080 Black Alligator Clip Qty 5 EC081 Red Alligator Clip Qty 5
-
EC413Spare Alligator clips for Potentiostats- Red, Green, Yellow (Qty 5 each)Cables and ConnectorsEC081 Red Alligator Clip (5 off) EC082 Green Alligator Clip (5 off) EC083 Yellow Alligator Clip (5 off)
-
EC414Yellow and Blue Alligator clips (Qty 5 each)Cables and ConnectorsEC083 Yellow Alligator Clip (Qty 5) EC084 Blue Alligator Clip (Qty 5)
-
EC450Female BNC to Mini clip adaptorCables and ConnectorsFemale BNC to Mini clip adaptor. 1 red and 1 black cable and clips to Female BNC. Nominal 150mm long
-
EC50012V AC-DC Desktop Power Supply 60WAccessoriesAC to DC external power adapter.Input 100 - 240V ~ 50/60Hz, 0.5AOutput 12V DC 5A 60W Max
-
EC5015V AC-DC Desktop Power Supply 5WAccessoriesAC to DC external power adapter. Input 100 - 240V ~ 50/60Hz, 1A Output 5V DC 1A 5W Max . Multiple AC plugs for international use. Suitable for use with EPU452 etc.
-
EC794ER815-OEM AdapterCables and ConnectorsNone
-
EC795Cable,ER28 I2C extension IOCables and ConnectorsNone
-
ED1621e-corder 1621Data Acquisition Systemse-corder 1621 is a 16 channel, continuous 400,000 s/s throughput 16 bit resolution data acquisition system with programmable gain. Twelve SE + four SE/differential inputs, 8/8 digital I/O, 4 Pod ports and a bipolar DAC output. Supports all eDAQ Amps and Pods. Communicates with PC via the Hi-Speed USB interface. Supplied with Chart and Scope software.
-
ED410e-corder 410Data Acquisition Systemse-corder 410 is a 4 Channel, continuous 100,000 s/s per channel, 24 bit resolution data acquisition system with programmable gain. Four SE/differential inputs , 4 Pod ports, a bipolar DAC output and 8/8 digital I/O. This unit supports all eDAQ Amps and Pods. Communicates with PC via the high speed USB interface. Supplied with Chart and Scope software.
-
ED821e-corder 821Data Acquisition Systemse-corder 821 is an 8 channel, continuous 400,000 s/s throughput, 16 bit resolution data acquisition system with programmable gain. Four SE + 4 SE/differential inputs, 8/8 digital I/O, 4 Pod ports and a bipolar DAC output. Supports all eDAQ Amps and Pods. Communicates with PC via the Hi-Speed USB interface. Supplied with Chart and Scope software.
-
ED832Microbial Growth Electronic Analyser Detection BoardResearch SystemsNone
-
EP352Biosensor isoPodisoPods (Non USB)The EP352 isoPod provides an isolated low current to Voltage converter suitable for use with a variety of current sources including 2 electrode amperometric biosensors and photodiodes. Can also be used as a low current ZRA. Baseline offset is provided to allow accurate recording of currents in the 2Ă_x0082_ÂľA to 2nA range.
-
EP353Isolated pH/ISE PodisoPods (Non USB)The EP353 isoPod provides a simple isolated interface to pH, ISE and Redox Electrodes with BNC input connectors. Also provides Hi Z measuring capability from +/- 200mV to +/-2000mV.
-
EP354Isolated dO2 PodisoPods (Non USB)The EP354 isoPod provides an isolated interface to a dissolved Oxygen Electrode. Adjustable poise voltage is available to suit the application. Current in the range 20Ă_x0082_ÂľA to 20nA is software selectable. Baseline offset is provided to allow more accurate recording small changes in oxygen concentrations.
-
EP355Isolated NO PodisoPods (Non USB)The EP355 isoPod provides an isolated interface to NO electrodes. Adjustable poise voltage is available to suit the application. Current in the range 2Ă_x0082_ÂľA to 2nA Full scale can be measured to meet the requirements of most NO electrodes. Baseline offset is provided to allow more accurate recording of small changes in NO concentrations.
-
EP356Isolated Thermocouple PodisoPods (Non USB)The EP356 isoPod provides a fast accurate universal and NIST polynomial calibrated thermocouple amplifier with Ice Point reference compensation. In the mV mode the system has a full scale range of +/-20mV with Ă_x0082_ÂľV resolution.
-
EP357Isolated Conductivity PodisoPods (Non USB)The EP357 isoPod provides a wide range of conductivity measurements from 200mS to 2Ă_x0082_ÂľS Full scale with K=1 electrodes. Suitable electrodes include the ET908 Flow-Thru Conductivity Electrode (0.093 ml), ET915 Dip-In Conductivity Electrode, ET916 Flow-Thru Conductivity Electrode (0.017 ml).
-
EP358RTD/Thermistor isoPodisoPods (Non USB)The EP358 isoPod provides an isolated, wide range of temperature measurements using 30K Thermistor probes for 0-70C and a 1000 Ohm RTD for -25-+250C precision measurements. The system is adaptable to other resistive temperature sensors.
-
EPU160MMB16 IO ExpanderInterface and Third Party ProdThis interface allows up to 16 TTL logic, or contact closure, signals to generate user defined comments in Chart using a virtual serial protocol over a USB port. The system is supplied with a Chart extension which allows easy use with e-corder 4, 8 and 16 channel systems. Alternatively the serial protocol can be used by users chosing to write their own software.
-
EPU352Biosensor isoPod with USB IOUSB isoPodsThe EPU352 is a USB based isoPod providing an isolated low current to Voltage converter suitable for use with a variety of current sources including 2 electrode amperometric biosensors and photodiodes. Baseline offset is provided to allow accurate recording of currents in the 2Ă_x0082_ÂľA to 2nA range. Supported by a serial protocol.
-
EPU353Isolated pH/ISE Pod with USB IOUSB isoPodsThe EPU353 isoPod provides a simple USB based isolated interface to pH, ISE and Redox Electrodes with BNC input connectors. Also provides Hi Z measuring capability from +/- 200mV and+/-2000mV. Supported by a serial protocol.
-
EPU354Isolated dO2 Pod with USB IOUSB isoPodsThe EPU354 is a USB based isoPod providing an isolated interface to a dissolved Oxygen Electrode. Adjustable poise voltage is available to suit the application. Current in the range 20Ă_x0082_ÂľA to 20nA is software selectable. Baseline offset is provided to allow more accurate recording small changes in oxygen concentrations. Supported by a serial protocol.
-
EPU355Isolated NO2 Pod with USB IOUSB isoPodsThe EPU355 is a USB based isoPod providing an isolated interface to NO electrodes. Adjustable poise voltage is available to suit the application. Current in the range 2Ă_x0082_ÂľA to 2nA Full scale can be measured to meet the requirements of most NO electrodes. Baseline offset is provided to allow more accurate recording of small changes in NO concentrations. Supported by a serial protocol.
-
EPU356Isolated Thermocouple Pod with USB IOUSB isoPodsThe EPU356 is a USB based isoPod providing a fast accurate universal and NIST polynomial calibrated thermocouple amplifier with Ice Point reference compensation. In the mV mode the system has a full scale range of +/-20mV with Ă_x0082_ÂľV resolution. Supported by a serial protocol.
-
EPU357Isolated Conductivity Pod with USB IOUSB isoPodsThe EPU357 is a USB based isoPod providing a wide range of conductivity measurements from 200mS to 2Ă_x0082_ÂľS Full scale with K=1 electrodes. Suitable electrodes include the ET908 Flow-Thru Conductivity Electrode (0.093 ml), ET915 Dip-In Conductivity Electrode, ET916 Flow-Thru Conductivity Electrode (0.017 ml). Supported by a serial protocol.
-
EPU358RTD/Thermistor isoPod with USB IOUSB isoPodsThe EPU358 is a USB based isoPod providing an isolated interface providing a wide range of temperature measurements using 30K Thermistor probes for 0-70C and a 1000 Ohm RTD for -25 to+250C precision measurements. The system is adaptable to other resistive temperature sensors.
-
EPU452Quad MF isoPod. Supports multiple sensor types. With USB connection.USB isoPodsThe EPU452 provides 4 individually isolated channels. Each channel can have an independently selectable function set by software: dO2/Amperometric Biosensor pH/ISE/ORP/HiZ mV Temperature (Thermistor 0-70C or RTD -25- +250C) Conductivity. The unit is powered and communicates directly via the USB bus. 20 - 24 bit ADC precision and 0.1% accuracy is provided. Supported by a serial protocol and includes a Pod-Vu License.
-
ER175Waveform GeneratorResearch SystemsThe ER175 is a programmable waveform generator designed to produce cyclic voltammetry waveforms capable of being controlled by user manual intervention. System can be programmed to produce other waveforms. Programmable trigger and digital input/output functions allow the system to control external recorders.
-
ER175Waveform GeneratorEnd of LifeThe ER175 is a programmable waveform generator designed to produce cyclic voltammetry waveforms capable of being controlled by user manual intervention. System can be programmed to produce other waveforms. Programmable trigger and digital input/output functions allow the system to control external recorders.
-
ER180CTwo Channel Mini-corder with Chart softwareData Acquisition SystemsThe ER180C is a dual channel data recording system. It consists of a hardware unit providing 24 bit resolution- 10 mV - 10V FS and sampling rates up to 1000/s. A single contact closure/TTL input is provided for trigger function and also Four Digital Output Contact closures. Communicates with PC via fast USB. Supplied with ES500 Chart and Scope software providing advanced recording and analysis capability. A suitable Trigger cable, if required , must be ordered separately.
-
ER180FTwo Channel Flow Injection Analysis SystemResearch SystemsThe ER180F is a dual channel Flow Injection Analyis data system. It consists of a hardware unit providing 24 bit resolution- 10 mV - 10V FS and sampling rates up to 1000/s. A single contact closure/TTL input is provided for trigger function. Communicates with PC via fast USB. Provided with ES500 Chart software with FIA and Event Manager extensions. Trigger cable, if required , must be ordered separately..
-
ER180RTwo Channel PowerChrom Chromatography Data SystemResearch SystemsThe ER180R is a dual channel chromatography data system. It consists of a hardware unit providing 24 bit resolution- 10 mV - 10V FS and sampling rates up to 100/s. A single contact closure/TTL input is provided for trigger function and also Four Digital Output Contact closures. Communicates with PC via fast USB. Supplied with PowerChrom software for recording and analysis of Chromatogrpahy data. Trigger cable, if required , must be ordered separately.
-
ER181COne channel Mini-corder with Chart SoftwareData Acquisition SystemsThe ER181C is a single channel data recording system. It consists of a hardware unit providing 24 bit resolution- 10 mV - 10V FS and sampling rates up to 2000/s. A single contact closure/TTL input is provided for trigger function. Communicates with PC via fast USB. Supplied with Chart and Scope software for recording and analysis of experimental data.
-
ER181FOne Channel Flow Injection Analysis SystemResearch SystemsThe ER181F is a single channel Flow Injection Analysis data system. It consists of a hardware unit providing 24 bit resolution- 10 mV - 10V FS and sampling rates up to 100/s. A single contact closure/TTL input is provided for trigger function. Communicates with PC via fast USB. Provided with ES500 Chart software with FIA and Event Manager extensions.
-
ER181ROne Channel PowerChrom Chromatography Data SystemResearch SystemsThe ER181R is a single channel chromatography data system. It consists of a hardware unit providing 24 bit resolution- 10 mV - 10V FS and sampling rates up to 100/s. A single contact closure/TTL input is provided for trigger function.. Communicates with PC via fast USB. Supplied with PowerChrom software for recording and analysis of Chromatography data. Trigger cable, if required , must be ordered separately.
-
ER181REOne Channel PowerChrom Chromatography Data System NTS EasyChrome softwareResearch SystemsThe ER181RE is a single channel chromatography data system. It consists of a hardware unit providing 24 bit resolution- 10 mV - 10V FS and sampling rates up to 100/s. A single contact closure/TTL input is provided for trigger function.. Communicates with PC via fast USB. Supplied with NTS EasyChrome software for recording and analysis of Chromatography data- Latest version to be downloaded.https://drive.google.com/file/d/1PBDQy4Gv-D_8TxEhoKakTpIX6xKNeAsL/view?usp=sharing PowerChrom license code included- Generate NEW license code Trigger cable, if required , must be ordered separately.
-
ER225C4D Data SystemResearch SystemsER225 is a complete C4D system consisting of a C4D amplifier (similar to the EA120) and a PowerChrom data system. Head stage excitation frequencies in the range 50kHz to 2MHz and 1V to 100Vpp amplitudes can be selected under computer control thus providing a wide dynamic range of conductivity measurements. Background conductivity can be offset to provide better resolution peak data. Requires suitable head stage.
-
ER225BC4D Data System - DC variantResearch SystemsThe ER225B is a complete C4D system (see ER225 for detail) provided with a 9-16 volt input power capability compatible with 12 volt batteries and AC to 12VDC power packs. It is suitable for field use if protected against weather. A suitable universal AC power pack is provided. The mains filter is not implemented. Suitable head stage must be ordered separately.
-
ER280PowerChrom 280 SystemResearch SystemsPowerChrom 280 is a 2 channel chromatography data system. It consists of data analysis and control software together with a hardware unit providing from 24 bit resolution, 20 mV - 10V FS and sampling rates up to 100/s. Four contact closure/TTL outputs and a single contact closure/TTL input are provided for control functions. Supplied with Windows XP & Vista compatible PowerChrom software. Communicates with PC via fast USB.
-
ER280BPowerChrom 280 System - DC Power versionResearch SystemsThe ER280B is a PowerChrom system (see ER280 for detail) provided with 9-16 volt input power compatible with 12 volt batteries and AC to 12VDC power packs. It is suitable for field use if protected against weather. A suitable universal AC power pack is provided. The mains filter is not implemented.
-
ER282Flow Injection Analysis SystemResearch SystemsA ER282 is a 2 channel Flow Injection recording, control and analysis system. It consists of a PowerChrom ER280 hardware unit with Chart software together with the Flow Injection Analysis and Event manager software extensions. Communicates with PC via fast USB. Supplied with Chart software.
-
ER282KFlow Injection AnalysisResearch SystemsA ER282 is a 2 channel Flow Injection recording, control and analysis system. It consists of a PowerChrom ER280 hardware unit with Chart software together with the Flow Injection Analysis and Event manager software extensions. Communicates with PC via fast USB. Supplied with Chart software.
-
ER430HV Sequencer - Quad HV supply for microfluidic chips.Research SystemsThe ER430 HV Sequencer is a system that provides four user programmable +/- 3 kV @100uA supplies. Each output can also be configured as voltage or current meters. Software is provided that controls the application of voltages in the sequence required to perform the experiment via an e-corder or independent USB connection.
-
ER455KER455 Microchip Electrophoresis KitKits and BundlesThe ER455K provides a complete Microchip Capillary Electrophoresis system consisting of an ER225, ER430 Quad High Voltage sequencer, EC020 Standards Test solutions, ET225 MCE platform and either ET145-4 or ET190-2 microchips (Please specify).
-
ER461KEChem Startup System, includes ER466, ES500, ES260, ET014Kits and BundlesThe ER461K is a complete electrochemistry laboratory consisting of a ER466C combination recorder and potentiostat, Chart, Scope and EChem Software, and an ET014 EChem Electrode kit.
-
ER466CIntegrated Potentiostat System - includes Chart and Scope softwareResearch SystemsER466C is a potentiostat system consisting of a 4 Channel e-corder system and an EA163 functionally equivalent potentiostat with some enhancements such as OCP function. In addition to current and potential recording channels two general purpose input channels (and matching Pod ports) are provided for ancillary measurements. Supplied with Chart and Scope software. Trigger cable, if required , must be ordered separately.
-
ER466CEIntegrated Potentiostat System - includes Chart, Scope and Echem softwareResearch SystemsER466CE is a potentiostat system consisting of a 4 Channel e-corder system and an EA163 functionally equivalent potentiostat with some enhancements such as OCP function. In addition to current and potential recording channels two general purpose input channels (and matching Pod ports) are provided for ancillary measurements. Supplied with Chart, Scope and EChem software. Trigger cable, if required , must be ordered separately.
-
ER466EIntegrated Potentiostat System - includes EChem softwareResearch SystemsER466C is a potentiostat system consisting of a 4 Channel e-corder system and an EA163 functionally equivalent potentiostat with some enhancements such as OCP function. In addition to current and potential recording channels two general purpose input channels (and matching Pod ports) are provided for ancillary measurements. Supplied with EChem software. Trigger cable, if required , must be ordered separately.
-
ER467CHigh Current Potentiostat- includes Chart and Scope softwareResearch SystemsER466C is a High Current Potentiostat consisting of a 4 Channel e-corder system and a 1 AMP potentiostat with some enhancements such as OCP function. In addition to current and potential recording channels two general purpose input channels and matching Pod ports are provided for ancillary measurements. Supplied with Chart and Scope software.
-
ER467CEHigh Current Potentiostat- includes Chart, Scope and EChem softwareResearch SystemsER466CE is a High Current Potentiostat consisting of a 4 Channel e-corder system and a 1 AMP potentiostat with some enhancements such as OCP function. In addition to current and potential recording channels two general purpose input channels and matching Pod ports are provided for ancillary measurements. Supplied with Chart, Scope and Echem software.
-
ER467EHigh Current Potentiostat- includes EChem softwareResearch SystemsER466C is a High Current Potentiostat consisting of a 4 Channel e-corder system and a 1 AMP potentiostat with some enhancements such as OCP function. In addition to current and potential recording channels two general purpose input channels and matching Pod ports are provided for ancillary measurements. Supplied with EChem software.
-
ER490ER490 Microchip electrophoresis experiments systemKits and BundlesThe ER490 kit includes: ER815R C4D Detector with PowerChrom software, ER430 High Voltage Sequencer, EC230 High Voltage Cables, ET121 Microchip Platform with C4D Electrodes including two ET195-2 Zeonor Chips, EC020 Standard Test Solution, ET067 Lead Wire Clamp
-
ER7004Mega Teaching KitKits and BundlesThe ER7004 eDAQ Mega teaching kit provides a broad range of hardware and software to replace expensive, single purpose analytical instruments and provides the means to implement interesting and dynamic learning opportunities in analytical chemistry. The kit contains:ER466 Integrated potentiostat, ET014 Electrode Kit, EP353 pH isoPod, ET5733 pH electrode, ET060 Redox Electrode, EP354 dO2 isoPod, ET1117 Oxygen electrode, EP356,Thermocouple isoPod, ET1400 T-Type Thermocouple probe, EP357 Conductivity isoPod, ET902 Conductivity probe, ET226 Drop Counter, ET1010 Pulse transducer, ET079-1 Copper disc Voltametric electrode, ET325 Thin Film Solar Cell. Chart, Scope, Echem and PowerChrom software.
-
ER7006MultiSensor Teaching KitKits and BundlesThis Multi Sensor Teaching Kit contains a EPU452 Quad MF isoPod and Pod-Vu software together with a set of commonly used sensors/electrodes used to measure pH,ISE, temperature, conductivity, dissolved oxygen, voltage and amperometric sensors etc. ET5733 Combination pH Electrode - Tuff tip for student use. ET060 ORP Electrode. Combination type - has internal reference. ET902 Conductivity Cell, k=1, 12 mm diameter glass body ET021 RTD Temperature Probe EC008 BNC to Pair of Alligator Clips REMOVED OCT 22 ET1117 Polarographic Oxygen Electrode- REMOVED OCT 22
-
ER70702 CH C4D Detector with headstage, Serial Protocol software and Trigger cable.Kits and BundlesThe ER7070 OEM kit consists of the following components: ER815-OEM detector PCB, ET120 headstage, Serial protocol software and an EC074orEC073 Trigger cable. Final PCB configuration to be confirmed.
-
ER7070C2 CH Contactless Conductivity Detector with head stage, Chart software and Trigger cable.Kits and BundlesThe ER7070C OEM kit consists of the following components: ER815-OEM detector PCB, ET120 headstage, ES500 Chart software and an EC074 Trigger cable. Final PCB configuration to be confirmed.
-
ER7070R2 CH C4D Detector with head stage, PowerChrom software and Trigger cable.Kits and BundlesThe ER7070R OEM kit consists of the following components: ER815-OEM detector PCB, ET120 headstage, ES280 PowerChrom software and an EC074 Trigger cable. Final PCB configuration to be confirmed.
-
ER7162Dual PicoStat BundleKits and BundlesThis is a Dual PicoStat bundle consisting of an ED410, EA362, ET014 and ES260
-
ER7303Standalone Potentiostat for CV applicationsKits and BundlesREPLACED BY ER466E
-
ER815Single channel C4D DetectorResearch SystemsThe ER815 Single channel C4D detector consists of a motherboard which supports 1 Input adaptor and head stage. It provides a selectable excitation signal in the range of 10kHz to 2MHz- and a low noise precision(22bit) detection signal processing. The system can output head stage data in analog form to a suitable e-corder (up to 8 channels) or PowerChrom unit (up to 2 channels) or customer data system. Serial data is also available on the USB port. Standard ER815 unit comes complete with 1 head stage adapters (EA025 ).
-
ER815-OEMC4D Detector SystemResearch SystemsC4D Detector System. A Two channel C4D detector with a C4D input and general purpose input. This pba is in a small format suitable for mounting inside a oem system
-
ER815-OEMCER815-OEM plus chartResearch SystemsEr815-OEM with chart licence and e-corder firmware
-
ER815CContactless Conductivity Detector with Chart - optional Trigger cable availableResearch SystemsThe ER815C is a single channel C4D detector/monitor supporting a single head stage (not included). It provides all required excitation signals to control a compatible head stage. Chart software is supplied to allow monitoring, recording and analysis of C4D data. Standard ER815C unit includes 1 (one) headstage adapter module (EA025). A suitable headstage and Trigger cable (if required) must be ordered separately.
-
ER815RContactless Conductivity Detector with PowerChrom optional Trigger cable availableResearch SystemsThe ER815R is a single channel C4D Chromatography detector and data system supporting a single head stage (not included). It provides all required excitation signals to control a compatible headstage. PowerChrom software is supplied to allow monitoring, recording and analysis of C4D peak data. Standard ER815R unit includes 1 (one) headstage adapter module (EA025). A suitable head stage and Trigger cable (if required) must be ordered separately.
-
ER818Octal Contactless Conductivity SystemKits and BundlesThe ER818 system was developed to enable the measurement of conductivity in samples with the following general characteristics: Low Sample Volumes, Low Sample Wastage, Zero Cross contamination, 100ÂľS/cm to 20,000 ÂľS/cm conductivity range suitable for operation in an automated system. The system consists of a Control unit (ER815) which provides an interface between a controlling PC and a suitable ET128 Octal headstage which is included with the system. Serial protocol is provided to control the unit and to acquire data at up to 1 scan of 8 channels per second. Control and communication between the ER818 system and the controlling PC is the responsibility of the Customer. A suitable Trigger cable, if required must be ordered separately.
-
ER825Multi Channel C4D Detector (Base unit only)Research SystemsThe ER825 Multi Channel C4D detector consists of a motherboard which supports from 1 to 8 Input modules( must be ordered seperately) and a combination of heads stages and auxiliary inputs. It provides an selectable excitation signal in the range of 10kHz to 2MHz, and a low noise precision(22bit) detection signal processing. The system can output head stage data in analog form to a suitable e-corder (up to 8 channels) or PowerChrom unit (up to 2 channels) or customer data system. Serial data is also available on the USB port. Each includes a EA025 Input module. ( Additional channels EA025 must be added at time of order)
-
ER825CMulti-Channel Contactless Conductivity Detector with Chart. Optional Trigger cable and input card availableResearch SystemsThe ER825C Multi Channel workstation supports from 1 to 8 Input modules, including EA025 and EA010 modules, to measure C4D and general purpose physical quantities. Each active channel requires an EA025 or an EA010 module (none fitted in basic unit). Chart Software is supplied with this system to provide recording and analysis functions at up to 400 samples per second/channel. A suitable C4D head stages and Trigger cable if required must be ordered separately.
-
ER825RTwo Ch (GP and C4D)Contactless Conductivity Detector with PowerChrom. Optional ch modules availableResearch SystemsThe ER825R Multi Channel workstation fitted with one EA025 and one EA010 module.. PowerChrom software (ES280) is supplied with this system to provide recording, analysis and peak detection functions on up to 2 channels. A suitable C4D headstages and Trigger cable if required must be ordered separately. Each includes a EA025 and EA010 Input module. ( Additional channels EA025 must be added at time of order)
-
ER832-16Microbial Growth Electronic Analyser-16 chResearch SystemsMicrobial Growth Electronic Analyser 16 channel
-
ER832-32Microbial Growth Electronic Analyser-32 chResearch SystemsMicrobial Growth Electronic Analyser 32 channel
-
ES017Ecorder firmware for C4D systemSoftware, Documentation, WarraThis firmware provides E-corder functions for ER-815 or ER-825 C4D systems.This will allow the Er8x5 series devices to operate with Powerchrom or Chart software( ordered separately). N.b Provides support for 2Ch max, must be installed at factory and ordered with C4D system.
-
ES260EChem Software Installer licenceSoftware, Documentation, WarraES260 EChem Software V2.x- Single user License and documentation. EChem is an electrochemistry data system which supports common electrochemical methods. Supports 100,000 s/s sampling rate and 16 bit resolution. It operates with the EA160 Potentiostat, EA162 Picostat as well as most customer supplied (analog driven) external Potentiostats. Latest version of software to be downloaded from eDAQ website. PowerChrom Licence to be supplied
-
ES261EChem Software - Departmental LicenseSoftware, Documentation, WarraEChem Software - Departmental License. Provides full set of software and documentation on USB together with a license to copy the software to other computers within a single department.
-
ES280PowerChrom SoftwareSoftware, Documentation, WarraPowerChrom v2.5 software is an advanced acquisition- analysis- control and reporting system for chromatography applications. Latest software to be downloaded from eDAQ website. PowerChrom licence to be supplied
-
ES281PowerChrom Software - Departmental LicenseSoftware, Documentation, WarraPowerChrom Software - Departmental License. Provides software and electronic documentation together with a license to copy the software to other computers within a single department.
-
ES282Flow Injection Analysis System Software LicenceSoftware, Documentation, WarraFlow Injection Analysis System Software to be downloaded from eDAQ wesite. FIA software licence to be supplied.
-
ES350Pod-Vu Software LicenceSoftware, Documentation, WarraPod-Vu software collects and displays signals from up to eight USB isoPod channels. Software license code printed on A6
-
ES500Chart & Scope Software LicenceSoftware, Documentation, Warra4 Channel Chart /Scope latest software is downloaded from eDAQ webiste for 2 and 4 channel e-corder systems. Chart provides multichannel, scrolling, continuous chart recording with powerful on-line computing and post-processing analysis functions. Scope provides 2 and 4 channel storage oscilloscope function with analysis.
-
ET014EChem Electrode KitAccessoriesThe ET014 EChem Electrode Kit contains PEEK encased gold, platinum and glassy carbon working electrodes, 3 mm OD, 1 mm active surface diameter; leakless Ag/AgCl reference electrode, 2 mm OD; platinum coated auxiliary electrode, 1.6 mm OD; and two 3 mL reaction vials with stand.
-
ET0211000 ohm Platinum RTD Temperature ProbeTransducersHigh Accuracy 1000 ohm Platinum RTD Temperature Probe inside a cylindrical stainless steel casing 5 mm OD. Grade AA sensor (formerly Grade 1/3 DIN). Used with EP358 isoPod
-
ET030Electrode Polishing KitAccessoriesThe ET030 Electrode Polishing Kit contains Glass Plates with rubber feet x 2Polishing Pads x 2 pkts0.30um Alumina Polishx 10.05um Alumina Polishx 1
-
ET031Glass plate with feetAccessories85mm square glass plate, 6mm deep. Arrissed ( rough polished )edges. Fitted with rubber feet
-
ET031-2Pair of ET031 glass plates with feetAccessoriesPair of ET031 glass plates with feet
-
ET032Polishing Cloth - Pack of 10AccessoriesPack of 10: MICROPAD 2 Polishing Cloth (2 7/8 inch dia)
-
ET0330.05 um alumina PowderAccessoriesNANO-1005-06 (0.05 um alumina slurry, 6 oz) 0.05 um alumina Powder Net 65gms
-
ET0340.3 um alumina PowderAccessoriesNANO-1003-06 (0.3 um alumina slurry, 6 oz) 0.3 um alumina Powder - Net 100gms
-
ET042pH Electrode. Combination type - has internal reference.TransducersThe ET042 pH Electrode is a Sealed Gel Double Junction electrode suitable for operation from 0-60C, pH range 0-14 pH. Double junction, Cable length 1m standard (Max 20m length Custom order, Connector BNC, Polypropylene Body, easily cleaned and suitable for low ionic strength or messy samples. Requires a EP353 pH isoPod.
-
ET044Flow Through pH electrodeTransducersA flow through pH electrode, for use with the EPU353 pH/ISE isoPod, EPU452 Quad Multifunction Isopod or EU168 Quad pH isopod. It has an internal volume of 0.8 ÂľL and connects to 3.2 mm ID tubing. Suitable for small volumes of biological fluids or similar aqueous solutions. Range of measurement is pH0 - 14 with proper calibration and flow control.
-
ET0513 mm Glassy carbon disk electrode in PEEK body, 6 mm ODTransducers3 mm Glassy carbon disk electrode in PEEK body, 6 mm OD
-
ET051-33 Pack ET051, 3 mm Glassy carbon disk electrode in PEEK body, 6 mm ODTransducersThree pack of ET051, 3 mm Glassy carbon disk electrode in PEEK body, 6 mm OD
-
ET0523 mm Platinum disk electrode in PEEK body, 6 mm ODTransducers3 mm Platinum disk electrode in PEEK body, 6 mm OD
-
ET052-33 Pack ET052, 3 mm Platinum disk electrode in PEEK body, 6 mm ODTransducersThree pack of ET052, 3 mm Platinum disk electrode in PEEK body, 6 mm OD
-
ET0533 mm gold disk electrode in PEEK body, 6 mm ODTransducers3 mm gold disk electrode in PEEK body, 6 mm OD
-
ET053-33 Pack ET053,3 mm Gold disk electrode in PEEK body, 6 mm ODTransducersThree pack of ET053, 3 mm Gold disk electrode in PEEK body, 6 mm OD
-
ET054Ag/AgCl Refillable reference electrode, 6 mm ODTransducersAg/AgCl Refillable reference electrode, 6 mm OD
-
ET054-33 Pack ET054 -Ag/AgCl Refillable reference electrode, 6 mm ODTransducersThree pack of ET054, Ag/AgCl reference electrode, 6 mm OD
-
ET055Platinum plate electrode (6.5 x 6.5 mm square) with glass bodyTransducersPlatinum plate electrode (6.5 x 6.5 mm square) with glass body
-
ET055-33 Pack ET055, Platinum plate electrode (6.5 x 6.5 mm square) with glass bodyTransducersThree pack of ET055, Platinum plate electrode (6.5 x 6.5 mm square) with glass body
-
ET0563 mm Copper disk electrode in PEEK body, 6 mm ODTransducersNone
-
ET056-33 Pack ET056,TransducersNone
-
ET0573 mm Silver disk electrode in PEEK body, 6 mm ODTransducersNone
-
ET057-33 Pack ET057TransducersNone
-
ET060ORP Electrode. Combination type - has internal reference.TransducersThe ET060 Combination ORP Electrode is suitable for operation from 0-60 C. Double junction, easily cleaned, suitable for messy or biological samples. Requires a EP353 isoPod.
-
ET066Flow cell for Zensor screen printed electrodesTransducersFlow cell for Zensor screen printed electrodes, especially ET083-40. Supplied with reference electrode and auxiliary electrode.
-
ET067Clamp for potentiostat electrode leads - Helping HandsAccessoriesClamp for potentiostat electrode leads. Also supplied as a part of ET014 electrode kit
-
ET068Cell holder for ET080 V-vial electrochemistry vesselsAccessoriesThis holds ET080 V-vial electrochemistry vessels upright. It is included in the ET014 electrode kit.
-
ET069-1Leakless Reference Electrode. 5mm Dia, O/A length 130mmTransducersLeakless Reference Electrode. 5mm Dia, O/A length 130mm
-
ET069-3.Leakless Reference Electrode. 5mm Dia, O/A length 130mm, Pack of 3TransducersLeakless Reference Electrode. 55mm Dia, O/A length 130mm, Pack of 3
-
ET070Hydrogen Reference electrode with 1 cartridge, wrench & allen keyTransducersThe ET070 is a modern Hydrogen Electrode with integrated hydrogen source making for convenient and safe operation. The hydrogen source is an easily replaceable cartridge with a typical lifetime of 6 months. Comes with 1 hydrogen cartridge. Supplied with Allen key to set hydrogen release rate, and hex spanner for cartridge replacement.
-
ET071Set of 4 refill cartridges for ET070TransducersGaskatel C 1/2 Refill Cartridge. pack of 4
-
ET072Leakless Ag/AgCl Miniature Reference Electrode. 2 mm ODTransducersLeakless Ag/AgCl Reference Electrode. Suitable for use in organic solvents. 2 mm OD x 45 mm barrel, 65 mm TOTAL length including strain relief and 1 mm pin connector.
-
ET072-3Pack of 3. Leakless Ag/AgCl Miniature Reference Electrode. 2 mm ODTransducersKit of three: Leakless Ag/AgCl Reference Electrode. Suitable for use in organic solvents. 2 mm OD x 65 mm length.
-
ET072SPCustomised Leak free electrode - Refer to notes for sizeTransducersNone
-
ET073Refillable Ag/AgCl Miniature Reference Electrode. 2.2 mm ODTransducersRefillable Ag/AgCl Miniature Reference Electrode. 2.2 mm OD.
-
ET073-3Pack of 3- ET073 Refillable Ag/AgCl Miniature Reference Electrode. 2.2 mm OD.TransducersKit of three ET073 Refillable Reference electrodes
-
ET074Glassy Carbon voltammetric 1mm disk, 3 mm OD, PEEK body electrodeTransducersGlassy Carbon voltammetric electrode. 3 mm OD, PEEK body. 1 mm diameter disk,
-
ET074-3Pack of 3: Glassy Carbon voltammetric disk electrodeTransducersPack of 3: Glassy Carbon voltammetric disk electrode
-
ET075Platinum voltammetric disk electrodeTransducersPlatinum voltammetric electrode. 3 mm OD, PEEK body. 1 mm diameter disk,
-
ET075-3Pack of 3: Platinum voltammetric disk electrodeTransducersPack of 3: Platinum voltammetric disk electrode
-
ET076Gold voltammetric disk electrodeTransducersGold voltammetric electrode. 3 mm OD, PEEK body. 1 mm diameter disk,
-
ET076-3Pack of 3: Gold voltammetric disk electrodeTransducersNone
-
ET077Pack of 40.;ZENSOR TE100 Screen Printed Voltammetric ElectrodesTransducersZensor TE100 screen printed electrodes. 3 mm carbon disk electrode, with outer annular crescent carbon auxiliary electrode, and Ag/AgCl pellet reference electrode. Pack of 40.
-
ET078Pt/Ti Titanium wire anode ET078TransducersPt-coated Titanium Auxiliary Electrode, 1.6 mm OD, length 70 mm, platinum coating 2.5 micron thick.
-
ET078-3Pack of 3: Pt-coated titanium wire electrode, 70 mmTransducersPt-coated titanium wire Electrode, 1.6 mm OD, length 70 mm, platinum coating 2.5 micron thick.
-
ET079Copper disc Voltammetric electrodeTransducersCopper voltammetric electrode. 3 mm OD, PEEK body. 1 mm diameter disk,
-
ET079-3Pack of 3: Copper voltammetric electrodeTransducersNone
-
ET080-12Electrochemical Reaction vessel, 3 mL, set of 12AccessoriesSet of 12 Electrochemical Reaction Vessels. supplied with open screw caps and silicone rubber lined gasket.
-
ET081-6Set of six Magnetic spin vanes for ET080AccessoriesNone
-
ET082-6Pack of 6: PTFE Drilled Gaskets for ET080TransducersNone
-
ET083ZENSOR SE100 Screen Printed Voltammetric ElectrodesTransducersZensor SE100 screen printed electrodes. 5 mm carbon disk electrode. Use with separate, conventional reference and auxiliary electrodes. Pack of 40.
-
ET084Mini Cell with AgitatorAccessoriesSmall glass jar (Wheaton W986297NG) and plastic stirrers 2 used in each ET014 set.
-
ET085Laboratory Arm for 12mm electrodesAccessoriesDesktop arm mount For 12mm electrodes.
-
ET086Pt/Ti Titanium wire anode 150mm longTransducersPt-coated Titanium Auxiliary Electrode, 1.6 mm OD, length 150 mm, platinum coating 2.5 micron thick.
-
ET086-3Pack of 3: Pt-coated titanium wire electrode 150mm longTransducersNone
-
ET087Nickel voltammetric disk electrodeTransducersNickel voltammetric electrode. 3 mm OD, PEEK body. 1 mm diameter disk,
-
ET087-1Nickel Disk ElectrodeTransducersNickel voltammetric electrode. 3 mm OD, PEEK body. 1 mm diameter disk,
-
ET087-3Nickel Disk Electrode, Three pack.TransducersNickel voltammetric electrode. 3 mm OD, PEEK body. 1 mm diameter disk,
-
ET088-1Silver disk electrodeTransducersSilver voltammetric electrode. 3 mm OD- PEEK body. 1 mm diameter disk-
-
ET088-3Silver disk electrode. Three packTransducersSilver voltammetric electrode. 3 mm OD- PEEK body. 1 mm diameter disk- Pack of 3
-
ET090-40Pack of 40: Kanichi Carbon Screen Printed ElectrodesTransducersThis SPE (Kanichi Carbon Screen Printed Electrodes) features a graphitic carbon working electrode, along with a carbon auxiliary electrode and Ag/AgCl reference. * Dimensions: 10 x 40 mm * Working electrode: 3 mm diameter disk, particulate graphitic carbon * Reference electrode: Ag/Agcl * Auxiliary electrode: particulate graphitic carbon. Supplied as a Pack of 40:
-
ET096Mini-Hydrogen electrodeTransducersET096 is a Mini-Hydrogen electrode. The hydrogen source must be replaced after 12 month. The head is made from PP and the shaft from PEEK the diameter of the shaft is just 1.6 mm. The head has a G 1/8'' BSP thread but it can also be used without being screwed in.The length of the shaft can be customized at additional cost. The connector lead is the same as used for the standard HydroFlex electrode (ET070) . It does not have a cartridge but a hydrogen generating button cell that lasts 12 months. Electrode has oring incl The material is FKM, the size 5.5mm ID diameter 1,2mm thickness.
-
ET097Replacement Hydrogen source for Mini-Hydrogen electrode ET096TransducersReplacement Hydrogen source/button cell for Mini-Hydrogen electrode ET096. The hydrogen source must be replaced after 12 months
-
ET098BVT Electrode AdapterTransducersBVT Electrode Adapter.This includes a PBA and and top and bottom cover2 o-rings and a data/instruction sheet
-
ET099Kanichi Electrode AdapterAccessoriesKanichi electrode adapter accepts eDAQ Kanichi electrodes (ET090, ET091, ET092, ET093, ET094, ET095) for mounting in ET080 reaction vessels (also ET014). Sockets for 2 mm pin, and studs for alligator clip connection are provided which are suitable for the electrode leads of all eDAQ Potentiostats.
-
ET1010Piezo-electric Pulse TransducerTransducersA small, rugged piezo electric vibration/acceleration transducer. The unit plugs directly into an e-corder input. It is not intended for quantitative acceleration measurements.
-
ET1115Galvanic Oxygen ElectrodeTransducersRugged, plastic body galvanic dissolved oxygen sensor. Response time 98% of final signal within 60 s. Temp range 0-50 C, output 35 mV Ă_x0082_Âą10 mV, 10-15Ă_x0082_ÂľA. The output, in air-saturated deionised water, is usually between 20-35 mV at 25 C with oxygen consumption on 3.45 x 10-13 Mole O2/s per mV of signal. Connects directly to a BNC input of an e-corder unit.
-
ET1120Micro-Oxygen Electrode (includes ET1121 Membrane Housing Kit)TransducersMicro-oxygen Electrode features low oxygen consumption- fast response (<20s) and requires less than a drop of liquid. Requires a EP354 isoPod to connect to an e-corder. Each electrode is supplied with an ET1121 Membrane Housing Kit consisting of six membranes- a bottle of electrolyte solution and a bulb pipette.
-
ET1121Replacement Membrane Housing Kit (for ET1120)TransducersReplacement Membrane Housing Kit (for ET1120).
-
ET117Membrane cap Kit for DO ET1117TransducersPack of two replacement Membrane for ET1117 DO probe
-
ET118Micro universal stirrer.AccessoriesMicro universal stirrer for ET1117 or similar sized probe
-
ET120C4D Head for C4D CE SystemTransducersC4D Head Stage for 360 Âľm OD capillary electrophoresis (CE) tubing. software selectable gains of x1 and x5 and rectifier. Connects to all eDAQ C4D amplifiers and systems.
-
ET121Microchip Platform with C4D ElectrodesTransducersThis unit consists of a mechanical adapter to position a Microchip CE channel to allow C4D measurements. This platform connects to all C4D amplifiers and systems. This configuration is optimized for use with MicroChips having a 100Âľm bottom cover plate thickness. This platform contains the detection electrodes, excitation source , x1, x5 software selectable gain, ET195-2 Microfluidic Chips
-
ET121-Lemo10ET121 C4D Microfluidic Platform with POD to Lemo 10 Way cableTransducersThis unit consists of a mechanical adapter to position a Microchip CE channel to allow C4D measurements. This platform connects to all C4D amplifiers and systems. This configuration is optimized for use with MicroChips having a 100Âľm bottom cover plate thickness. This platform contains the detection electrodes, excitation source , x1, x5 software selectable gain. This line item uses Cable, POD to Lemo 10 Way, EAID-00489-cab, instead of EAID-00019-cab
-
ET125General Purpose C4D headTransducersC4D Head stage suitable for contactless conductivity detection for 1/16 inch tubing. The head stage contains the excitation and detection circuits with x1, x5 software selectable gain and signal detection. Electrode separation is 9 mm
-
ET128Octal C4D headTransducersC4D Head stage suitable for contactless conductivity detection for 1/16 inch tubing. The head stage contains the excitation and detection circuits with x1, x5 software selectable gain and signal detection. Electrode separation is 9 mm
-
ET130IC/HPLC C4D headTransducersC4D Head stage suitable for contactless conductivity detection for 1/16 inch tubing. The head stage contains the excitation and detection circuits with x1, x5 software selectable gain and signal detection. Electrode
-
ET131Configurable General Purpose C4D headTransducersC4D Head stage suitable for contactless conductivity detection for 1/16in,1/32in & 380 micron tubing. The head stage contains the excitation and detection circuits with x1, x5 software, selectable gain and signal detection. Electrode separation is 4-9 mm
-
ET1400T-Type Thermocouple Probe - miniature.TransducersMiniature, precision T-Type thermocouple probe for liquids, gases and semisolids. Plastic handle with straight 75 mm stainless shaft, 1.5 mm diameter. Maximum temperature: 400degC, Time constant 0.5 secs, lead length: 1.5m. Suitable for use with EP356/EPU356 isoPod.
-
ET145-4Microchip , Pack of 4, 45mmAccessories45mm Micronit microfluidic chip with C4D electrodes, model number 35100C4D. Pack of four. Can be used with ET225 chip holder, ER230 HV Sequencer, and any eDAQ C4D Amp/detector.
-
ET16Electrode simulatorTransducersThe ET16 is a 6 way switched resistor network that simulates a range of electrochemical electrodes ranging in currents from 10mA to 100pA full scale. It provides a simple means of testing the operation of Potentiostats, Quadstat systems and isoPods.This electrode simulator is intended to be used to test Potentiostats and QuadStats.
-
ET1600pH micro Electrode - 1.6mm OD, 50mm tip lengthTransducersA miniature combination pH electrode suitable for use in a capillary flow through systems. Available in 1600Âľ tip diameter and body lengths of 20 mm. Active tip is less than 1 mm long. A Reference electrode is not required. Suitable for use with EPU353, EPU452 and EU168 isoPods. Other tip diameters(650u, 1000u) and lenghts (50, 75mm) are available on special order. Potential shifting device available. PSD not required with isoPods
-
ET1601MINI Ion Selective Electrode (Ca2+) CalciumTransducers2.5mm Half-cell MINI Electrode-(Ca2+) Calcium, Length 45 mm, work with Cable: BNC to crocodile/alligator clips, line item EC08
-
ET1602MINI Ion Selective Electrode (Cl-) ChlorideTransducers2.5mm Half-cell MINI Electrode-(Cl-) Chloride, Length 45 mm, work with Cable: BNC to crocodile/alligator clips, line item EC08
-
ET1603MINI Ion Selective Electrode (Cu2+) CopperTransducers2.5mm Half-cell MINI Electrode-(Cu2+) Copper, Length 45 mm, work with Cable: BNC to crocodile/alligator clips, line item EC08
-
ET1604Nano Ion Selective Electrode for Fluoride (F-)TransducersNano Ion Selective Electrode for Fluoride (F-), Length 45 mm, work with Cable: BNC to crocodile/alligator clips, line item EC008 SKU: M019
-
ET1605MINI Ion Selective Electrode (K+) PotassiumTransducers2.5mm Half-cell MINI Electrode-(K+) Potassium, Length 45 mm, work with Cable: BNC to crocodile/alligator clips, line item EC08
-
ET1606Nano Ion Selective Electrode (Li+) LithiumTransducers2.5mm Half-cell MINI Electrode-(Li+) Lithium, Length 45 mm, work with Cable: BNC to crocodile/alligator clips, line item EC08
-
ET1607MINI Ion Selective Electrode (Mg2+) MagnesiumTransducers2.5mm Half-cell MINI Electrode-(Mg2+) Magnesium, Length 45 mm, work with Cable: BNC to crocodile/alligator clips, line item EC08
-
ET1608MINI Ion Selective Electrode (Na+) SodiumTransducers2.5mm Half-cell MINI Electrode-(Na+) Sodium, Length 45 mm, work with Cable: BNC to crocodile/alligator clips, line item EC08
-
ET1609Nano Ion Selective Electrode for Ammonium (NH4+)TransducersNano Ion Selective Electrode for Ammonium (NH4+), Length 45 mm, work with Cable: BNC to crocodile/alligator clips, line item EC08
-
ET1610MINI Ion Selective Electrode (NO2-) NitriteTransducers2.5mm Half-cell MINI Electrode-(NO2-) Nitrite, Length 45 mm, work with Cable: BNC to crocodile/alligator clips, line item EC08
-
ET1611MINI Ion Selective Electrode (NO3-) NitrateTransducers2.5mm Half-cell MINI Electrode-(NO3-) Nitrate, Length 45 mm, work with Cable: BNC to crocodile/alligator clips, line item EC08
-
ET1612MINI Ion Selective Electrode pH (CNT_ISE)Transducers2.5mm Half-cell MINI Electrode-pH (CNT_ISE), Length 45 mm, work with Cable: BNC to crocodile/alligator clips, line item EC08
-
ET1613MINI Ion Selective Electrode ReferenceTransducers2.5mm Half-cell MINI Electrode-Reference, Length 45 mm, work with Cable: BNC to crocodile/alligator clips, line item EC08
-
ET1614MINI Ion Selective Electrode (ClO4-) PerchlorateTransducers2.5mm Half-cell MINI Electrode-(ClO4-) Perchlorate, Length 45 mm, work with Cable: BNC to crocodile/alligator clips, line item EC08
-
ET1615MODULAR Ion Selective Electrode (Ca2+) Calcium, work with Single/Multi ProbeTransducers4.6 mm Half-cell MODULAR Electrode-(Ca2+) Calcium, Length 50 mm, work with Single/Multi Probe, line item ET1632/ET1633
-
ET1616MODULAR Ion Selective Electrode (Cl-) Chloride, work with Single/Multi ProbeTransducers4.6 mm Half-cell MODULAR Electrode-(Cl-) Chloride, Length 50 mm, work with Single/Multi Probe, line item ET1632/ET1633
-
ET1617MODULAR Ion Selective Electrode (Cu2+) Copper, work with Single/Multi ProbeTransducers4.6 mm Half-cell MODULAR Electrode-(Cu2+) Copper, Length 50 mm, work with Single/Multi Probe, line item ET1632/ET1633
-
ET1618MODULAR Ion Selective Electrode (F-) Fluoride, work with Single/Multi ProbeTransducers4.6 mm Half-cell MODULAR Electrode-(F-) Fluoride, Length 50 mm, work with Single/Multi Probe, line item ET1632/ET1633
-
ET1619MODULAR Ion Selective Electrode (K+) Potassium, work with Single/Multi ProbeTransducers4.6 mm Half-cell MODULAR Electrode-(K+) Potassium, Length 50 mm, work with Single/Multi Probe, line item ET1632/ET1633
-
ET1620MODULAR Ion Selective Electrode (Li+) Lithium, work with Single/Multi ProbeTransducers4.6 mm Half-cell MODULAR Electrode-(Li+) Lithium, Length 50 mm, work with Single/Multi Probe, line item ET1632/ET1633
-
ET1621MODULAR Ion Selective Electrode (Mg2+) Magnesium, work with Single/Multi ProbeTransducers4.6 mm Half-cell MODULAR Electrode-(Mg2+) Magnesium, Length 50 mm, work with Single/Multi Probe, line item ET1632/ET1633
-
ET1622MODULAR Ion Selective Electrode (Na+) Sodium, work with Single/Multi ProbeTransducers4.6 mm Half-cell MODULAR Electrode-(Na+) Sodium, Length 50 mm, work with Single/Multi Probe, line item ET1632/ET1633
-
ET1623MODULAR Ion Selective Electrode (NH4+) Ammonium, work with Single/Multi ProbeTransducers4.6 mm Half-cell MODULAR Electrode-(NH4+) Ammonium, Length 50 mm, work with Single/Multi Probe, line item ET1632/ET1633
-
ET1624MODULAR Ion Selective Electrode (NO2-) Nitrite, work with Single/Multi ProbeTransducers4.6 mm Half-cell MODULAR Electrode-(NO2-) Nitrite, Length 50 mm, work with Single/Multi Probe, line item ET1632/ET1633
-
ET1625MODULAR Ion Selective Electrode (NO3-) Nitrate, work with Single/Multi ProbeTransducers4.6 mm Half-cell MODULAR Electrode-(NO3-) Nitrate, Length 50 mm, work with Single/Multi Probe, line item ET1632/ET1633
-
ET1626MODULAR Ion Selective Electrode pH (CNT_ISE), work with Single/Multi ProbeTransducers4.6 mm Half-cell MODULAR Electrode-pH (CNT_ISE), Length 50 mm, work with Single/Multi Probe, line item ET1632/ET1633
-
ET1627MODULAR Ion Selective Electrode Reference, work with Single/Multi ProbeTransducers4.6 mm Half-cell MODULAR Electrode-Reference, Length 50 mm, work with Single/Multi Probe, line item ET1632/ET1633
-
ET1628MODULAR Ion Selective Electrode (ClO4-) Perchlorate, work with Single/Multi ProbeTransducers4.6 mm Half-cell MODULAR Electrode-(ClO4-) Perchlorate, Length 50 mm, work with Single/Multi Probe, line item ET1632/ET1633
-
ET1629MODULAR Ion Selective Electrode (Ag+) Silver, work with Single/Multi ProbeTransducers4.6 mm Half-cell MODULAR Electrode-(Ag+) Silver, Length 50 mm, work with Single/Multi Probe, line item ET1632/ET1633
-
ET1630MODULAR Ion Selective Electrode (Br-) Bromide, work with Single/Multi ProbeTransducers4.6 mm Half-cell MODULAR Electrode-(Br-) Bromide, Length 50 mm, work with Single/Multi Probe, line item ET1632/ET1633
-
ET1631MODULAR Ion Selective Electrode (I-) Iodide, work with Single/Multi ProbeTransducers0.0
-
ET1633Multi ION Probe for up to 7 Modular ElectrodesTransducers25 mm Multi ION Probe for up to 7 Modular Electrodes.Customize your own probe, multiple electrodes in a small size handy probe. Diameter 25 mm, length 150 mm, Connector M12 / 7xBNC /Other, Cable 1m. Other terminations, available IONS:(NH4+) Ammonium(NO2-) Nitrite(NO3-) NitratepH (CNT_ISE)Reference Electrode(ClO4-) Perchlorate(Ag+) Silver(Br-) Bromide(I-) Iodide(Ca2+) Calcium(Cl-) Chloride(Cu2+) Copper(F-) Fluoride(K+) Potassium(Li+) Lithium(Mg2+) Magnesium(Na+) Sodium
-
ET1634Single Ion Probe with Mini Electrode inserted (Ca2+) CalciumTransducersSingle Ion Probe with Mini Electrode inserted (Cl-) Chloride, Diameter 12 mm, Length 145 mm, Connector BNC, Cable 1m, 3m or 5m length; Use with Standard Ion/mV/pH ISO Pod.Works with a (Ca2+) Calcium Electrode MODULAR ION Electrode
-
ET1635Single Ion Probe with Mini Electrode inserted (Cl-) ChlorideTransducersSingle Ion Probe with Mini Electrode inserted (Cl-) Chloride, Diameter 12 mm, Length 145 mm, Connector BNC, Cable 1m, 3m or 5m length; Use with Standard Ion/mV/pH ISO Pod.Works with a (Cl-) Chloride Electrode MODULAR ION Electrode
-
ET1636Modular Single Ion Selective Electrode (Cu2+) CopperTransducersSINGLE ION with probe and MODULAR ION, Diameter 12 mm, Length 145 mm, Connector BNC, Cable 1m, 3m or 5m length; Use with Standard Ion/mV/pH ISO Pod.Works with a (Cu2+) Copper Electrode MODULAR ION Electrode
-
ET1637Single Ion Probe with Mini Electrode inserted (F-) FluorideTransducersSingle Ion Probe with Mini Electrode inserted (F-) Fluoride, Diameter 12 mm, Length 145 mm, Connector BNC, Cable 1m, 3m or 5m length; Use with Standard Ion/mV/pH ISO Pod.Works with a (F-) Fluoride Electrode MODULAR ION Electrode
-
ET1638Single Ion Probe with Mini Electrode inserted (K+) PotassiumTransducersSingle Ion Probe with Mini Electrode inserted (Cl-) Chloride, Diameter 12 mm, Length 145 mm, Connector BNC, Cable 1m, 3m or 5m length; Use with Standard Ion/mV/pH ISO Pod.Works with a (K+) Potassium Electrode MODULAR ION Electrode
-
ET1639Single Ion Probe with Mini Electrode inserted (Li+) LithiumTransducersSingle Ion Probe with Mini Electrode inserted (Li+) Lithium, Diameter 12 mm, Length 145 mm, Connector BNC, Cable 1m, 3m or 5m length; Use with Standard Ion/mV/pH ISO Pod.Works with a (Li+) Lithium Electrode MODULAR ION Electrode
-
ET1640Single Ion Probe with Mini Electrode inserted (Mg2+) MagnesiumTransducersSingle Ion Probe with Mini Electrode inserted (Mg2+) Magnesium, Diameter 12 mm, Length 145 mm, Connector BNC, Cable 1m, 3m or 5m length; Use with Standard Ion/mV/pH ISO Pod.Works with a (Mg2+) Magnesium Electrode MODULAR ION Electrode
-
ET1641Single Ion Probe with Mini Electrode inserted (Na+) SodiumTransducersSingle Ion Probe with Mini Electrode inserted (Na+) Sodium, Diameter 12 mm, Length 145 mm, Connector BNC, Cable 1m, 3m or 5m length; Use with Standard Ion/mV/pH ISO Pod.Works with a (Na+) Sodium Electrode MODULAR ION Electrode
-
ET1642Single Ion Probe with Mini Electrode inserted (NH4+) AmmoniumTransducersSingle Ion Probe with Mini Electrode inserted(NH4+) Ammonium, Diameter 12 mm, Length 145 mm, Connector BNC, Cable 1m, 3m or 5m length; Use with Standard Ion/mV/pH ISO Pod.Works with a (NH4+) Ammonium Electrode MODULAR ION Electrode
-
ET1643Single Ion Probe with Mini Electrode inserted (NO2-) NitriteTransducersSingle Ion Probe with Mini Electrode inserted (NO2-) Nitrite, Diameter 12 mm, Length 145 mm, Connector BNC, Cable 1m, 3m or 5m length; Use with Standard Ion/mV/pH ISO Pod.Works with a (NO2-) Nitrite Electrode MODULAR ION Electrode
-
ET1644Single Ion Probe with Mini Electrode inserted (NO3-) NitrateTransducersSingle Ion Probe with Mini Electrode inserted (NO3-) Nitrate, Diameter 12 mm, Length 145 mm, Connector BNC, Cable 1m, 3m or 5m length; Use with Standard Ion/mV/pH ISO Pod.Works with a (NO3-) Nitrate Electrode MODULAR ION Electrode
-
ET1645Half-cell Ion Selective Electrode for pH incl probe(CNT_ISE)TransducersSINGLE ION with probe and MODULAR ION, Diameter 12 mm, Length 145 mm, Connector BNC, Cable 1m, 3m or 5m length; Use with Standard Ion/mV/pH ISO Pod.Works with a pH (CNT_ISE) Electrode MODULAR ION Electrode
-
ET1646Single Ion Probe with Mini Reference Electrode insertedTransducersSingle Ion Probe with Mini Reference Electrode inserted, Diameter 12 mm, Length 145 mm, Connector BNC, Cable 1m, 3m or 5m length; Use with Standard Ion/mV/pH ISO Pod.Works with a Reference Electrode MODULAR ION Electrode
-
ET1647Single Ion Probe with Mini Electrode inserted (ClO4-) PerchlorateTransducersSingle Ion Probe with Mini Electrode inserted (Br-) Bromide, Diameter 12 mm, Length 145 mm, Connector BNC, Cable 1m, 3m or 5m length; Use with Standard Ion/mV/pH ISO Pod.Works with a (ClO4-) Perchlorate Electrode MODULAR ION Electrode
-
ET1648Modular Single Ion Selective Electrode (Ag+) SilverTransducersSINGLE ION with probe and MODULAR ION, Diameter 12 mm, Length 145 mm, Connector BNC, Cable 1m, 3m or 5m length; Use with Standard Ion/mV/pH ISO Pod.Works with a (Ag+) Silver Electrode MODULAR ION Electrode
-
ET1649Single Ion Probe with Mini Electrode inserted (Br-) BromideTransducersSingle Ion Probe with Mini Electrode inserted (Br-) Bromide, Diameter 12 mm, Length 145 mm, Connector BNC, Cable 1m, 3m or 5m length; Use with Standard Ion/mV/pH ISO Pod.Works with a (Br-) Bromide Electrode MODULAR ION Electrode
-
ET1650Single Ion Probe with Mini Electrode inserted (I-) IodideTransducersSingle Ion Probe with Mini Electrode inserted (I-) Iodide, Diameter 12 mm, Length 145 mm, Connector BNC, Cable 1m, 3m or 5m length; Use with Standard Ion/mV/pH ISO Pod.Works with a (I-) Iodide Electrode MODULAR ION Electrode
-
ET190-2Microchip , Pack of 2, 90mmAccessories90mm Micronit microfluidic chip with C4D electrodes, model number T85100C4D. Pack of two. Can be used with ET225 chip holder, ER430 HV Sequencer, and any eDAQ C4D Amp/detector.
-
ET195-2Microchip , Pack of 2, 90mmInterface and Third Party ProdThis line item contains QTY 2 units Cross-shaped channel chip- platform IFludic interface: Luer Channel width: 75 Âľm / Channel depth: 75Âľm / Channel length: 87.0 mmHole Diameter: 1.0 mm / Material: Zeonor /Lid thickness: 100 Âľm
-
ET225MCE AdapterTransducersET225 is microfluidic chip adapter specially configured to hold Micronit 45 (or 90 mm) microfluidic chips together will all necessary HV connections. The C4D circuit board is an integral part of this adapter and connects directly to the any eDAQ C4D system. Interlocks are provided to allow safe operation of the system in the presence of internal High voltages.
-
ET226Drop CounterTransducersDrop counter for student titrations uses a pulsed infrared light source and reflective detector to produce an electrical pulse (5 V resting to 0 V pulse) every time a drop passes. Connects to e-corder Pod port. Used with Chart software which counts the pulses and converts the cumulative count to a volume measurement. Commonly used with a pH or Conductivity isoPod, for titration experiments.
-
ET325-5Thin film solar cell, 3V, 25 mA (five pack)AccessoriesA five pack of flexible thin film, amorphous silicon, solar cells that are ideal for teaching the principles of solar energy collection. Use with a potentiostat system to: determine the open circuit potential (maximum voltage, Vmax); determine short circuit current (maximum current, imax); ramp the potential from zero to Vmax and prepare a graph of i vs V multiply the iV and V signals to get the work signal; and then repeat at different illumination levels. Electrical: 3 V, 25 mA. Dimensions w x h: 25 x 114 mm
-
ET405K-type Temperature ProbeTransducersHand held tubular stainless steel K thermocouple temperature probe suitable for use in fluids in the temperature range of -25Ă_x0082_ÂĄC to 200 Ă_x0082_ÂĄC. Fitted with 2 pin mini K thermocouple connector to suit EP356/EPU356 Thermocouple isoPod.
-
ET5733Combination pH ElectrodeTransducersCombination pH electrode is suitable for operation from 0-60 deg C, 0-14 pH. Cleanliness of the sensor and junction is critical for accurate measurement. These features make this electrode an excellent alternative to conventional pH electrodes where there is a risk of bulb breakage, such as during laboratory classes. Requires an EP353/EPU356 pH isoPod.
-
ET901Conductivity Cell, k=0.1, 12 mm diameter glass bodyTransducersConductivity Cell, k=0.1, 12 mm diameter, 120 mm long, glass body, fitted with 1 m cable with BNC termination. Use with low conductivity solutions (<0.1 mS/cm). Suitable for use with a EP357/EPU35 Conductivity isoPod.
-
ET902Conductivity Cell, k=1, 12 mm diameter glass bodyTransducersConductivity Cell, k=1, 12 mm diameter, 120 mm long, glass body, fitted with 1 m cable with BNC termination. Use with solutions up to 100 mS/cm. Suitable for use with a EP357/EPU35 Conductivity isoPod.
-
ET903Conductivity Cell, k=10, 12 mm diameter glass bodyTransducersConductivity Cell, k=10, 12 mm diameter, 120 mm long, glass body, fitted with 1 m cable with BNC termination. Use with high conductivity solutions (>100 mS/cm). Suitable for use with a EP357/EPU35 Conductivity isoPod.
-
ET908Flow-Thru Conductivity Electrode. k=1. Fits 1/8" ID tubing.TransducersFlow through Conductivity Electrode, 4.3 cm long, 1m lead, 8 mm body, cell volume 0.093 ml, cell constant approximatly x1, T fitting 1/8" (3.2 mm ID tubing), material ABS. Suitable for use with a EP357/EPU35 Conductivity isoPod. Also 16-900 for 1/16" tubing
-
ET915Dip-In Conductivity Electrode. k=1. Body is 3.2 mm diameter.TransducersConductivity electrode for immersion, 14.6 cm long, lead length 1m, 3.2 mm body, cell constant approximatly x1, immersion depth 5 mm. Construction ABS. Suitable for use with a EP357/EPU357 Conductivity isoPod.
-
ET916Flow-Thru Conductivity Electrode. k=1. Fits 1/16" ID tubing.TransducersFlow through conductivity electrode, 4.2 cm long, lead length 1m, 6.4 mm body, cell volume 0.017 ml, cell constant approx. 1, T fitting 1/16" (1.6 mm ID tubing), material ABS. Suitable for use with a EP357/EPU357 Conductivity isoPod.
-
EU168Quad isolated pH/ISE podUSB isoPodsThe EU168 provides 4 group isolated amplifiers capable of measuring pH, ISE and +/-2000mV, The unit is powered and communicates directly via the USB bus. 20 - 24 bit ADC precision and 0.1 accuracy is provided. A range of software tools are provided including serial commands. This unit was specifically developed for TECAN.
-
FARAD2Faraday CageAccessoriesThe faraday case, Farad2, is an essential item for electroanalytical experiments. It is well designed to block out external EMI noise and firmly enclosure all the components of electrochemical cell (electrodes, vials, etc.). The spacious interior allows you to set up electronic components or systems easily.
-
SDx-A1tethaPlate Assembly JigSDx ProductsThis press clamps the white polycarbonate 6-chamber tethaPlate cartridge to the transparent polycarbonate slide (on which the 6 tether-plated god gold working electrodes electrodes are located) during the adhesion step.The final tethaPlate assemby is now ready for phospholipid membrane creation and ion channel insertion for measurements with a tethaPod or tethaPatch experiment.SpecificationsVolume: 1 mLTotal lipid concentration: 3 mM in ethanolLipid mixture: diphytanyletherphosphatidylcholine 70%, and glycerodiphytanylether 30%Long term storage: 4Ă_x0082_°CUsage: 0 45Ă_x0082_°C
-
SDx-A2tethaPod Test CardSDx ProductsThe SDx tethaPod Test Card provides standard rerstance and capacitance values to each of the six channels of the tehaPod. It is used to ensure that all tethaPod or tethPatch channels are working correcty. It is positioned in place of the standard tethaPlate modules. Specifications Membrane resistance, Rm: 1 MohmMembrance Capacitance, Cm: 10 nFSeries Capacitance, Cs: 100 nF
-
SDx-APP2tethaQuick SoftwareSDx ProductstethaQuick SoftwareThis software is for tethaPod units built May 2015 or later
-
SDx-BGSDx-BGSDx Productsa bare gold electrode thethaPlate. tethaPlate - 10 pack Long term storage: 4Ă_x0082_°C Usage: 0-45 deg C
-
SDx-MK1SDx Mega KitSDx ProductsThis kit enables both continous membrane conductance monitoring, and voltage clamp style experiments on tethered membrane systems and comprises: SDx-R5 tethaPod Starter Kit, SDx-R2 tethaPatch unit, ER466 Integrated Potentiostat System and ES260 EChem software
-
SDx-R1tethaPodSDx ProductsSDX tethaPod Plate Reader with USB interface
-
SDx-R2TethaPatchSDx ProductsSDXTethaPatch Multiplexer
-
SDx-R5tethaPod start-up kitSDx ProductstethaPod Starter kit comprising: 1 x SDx-R1 tethaPod 1 x SDx-A2 Test Card 10 x SDx-T10 tethaPlate assembly 1 x SDx-S1 Lecond Layer lipids 1 x SDx-A1 Clamp and slide assembly jig
-
SDx-S1Phospholipid mixSDx ProductsA 1 mL vial containing a ethanolic solution of lipids suitable for phospholipid bilayer membrane formation when used with a tethaPlate. SpecificationsVolume: 1 mLTotal lipid concentration: 3 mM in ethanolLipid mixture: diphytanyletherphosphatidylcholine 70%, and glycerodiphytanylether 30%Long term storage: 4Ă_x0082_°CUsage: 0 45Ă_x0082_°C
-
SDx-T10tethaPlate - 10 packSDx ProductsThe tethaPlate is a 6-chamber sample holder for tethered membrane preparations. It is used in conjunction with a tethaPod or tethaPatch system for the determination of membrane conduction and studies of protein ion channels. The working electrodes are pre-coated with tethering agent and the plate is ready for the addition of phospholipids for membrane creation. The tether/spacer ratio is normally set at 1:10. Other ratios can be supplied on special order. The tethaPlate is delivered in two sections which are assembled with the aid of an Assembly Jig. Sample chambers. Tethers: benzyl-disulphide-bis-tetraethyleneglycolmonophytane. Spacers: benzyl-disulphide-bis-tetraethyleneglycolTether/Spacer ratio: 1/10. Long term storage: 4Ă_x0082_°C Usage: 0-45 deg C
-
SDx-T10-5tethaPlate -5 packSDx ProductsThe tethaPlate is a 6-chamber sample holder for tethered membrane preparations. It is used in conjunction with a tethaPod or tethaPatch system for the determination of membrane conduction and studies of protein ion channels. The working electrodes are pre-coated with tethering agent and the plate is ready for the addition of phospholipids for membrane creation. The tether/spacer ratio is normally set at 1:10. Other ratios can be supplied on special order. The tethaPlate is delivered in two sections which are assembled with the aid of an Assembly Jig. Sample chambers. Tethers: benzyl-disulphide-bis-tetraethyleneglycolmonophytane. Spacers: benzyl-disulphide-bis-tetraethyleneglycolTether/Spacer ratio: 1/10. Long term storage: 4 Ă_x0082_°C Usage: 0-45 deg C
-
SP100SP1 Electrochemical Workstation.InstrumentsSP1 Electrochemical Workstation. 1MHz, 1 Amp,10Volt compliance Includes following software modules: Energy(Battery) test software package BATe EIS software package EISe Electrochemical analysis software package EASe Corrosion test software package CORe
-
SP200SP2 Electrochemical Workstation. 1MHz, 2 Amp, 10Volt complianceInstrumentsSP2 Electrochemical Workstation. 1MHz, 2 Amp/10Volt compliance. Includes folloing softwre modules: Energy(Battery) test software package BATe EIS software package EISe Electrochemical analysis software package EASe Corrosion test software package CORe