  • EA010
    GP Analog module for ER825 PBA
    Research Systems
    EA010 is a General Purpose module required to connect DC signal of +/-10V to an ER825 system. It provides an 8 Pin Input connector which can control analog Isopods. Gain, filter settings and offset are all software controlled. Up to 8 EA010 couplers can be fitted in one ER825 system. This req the pod adapter cable
  • EA025
    C4D MODULE PBA
    Research Systems
    EA025 is a C4D head stage module required to connect a C4D head stage to an ER825 system. It provides push pull excitation frequencies (10 kHz to 2MHz) and amplitudes (100mV to 20Vpp). Gain, filter settings and offset are all software controlled. In addition it identifies head stage type and settings on future head stages fitted with flash memory. Up to 8 EA025 couplers can be fitted in one ER825 system.
  • EA120
    C4D Amp
    Amplifiers & Potentiostats
    EA120 Contactless Capacitively Coupled Conductivity Detector (C4D) amplifier, suitable for all eDAQ C4D Head stages. A wide range of excitation frequencies (100 kHz to 2MHz) and amplitudes (.2 to 20Vpp) can be applied to the detector under computer control thus providing a wide dynamic range of conductivity measurements. Background conductivity can be offset to provide better resolution peak data. The C4D Amp connects to any e-corder system which provides power and control and supported by PowerChrom or Chart software. Head stage must be ordered separately
  • EA163
    Potentiostat EA163
    Amplifiers & Potentiostats
    The EA163 Potentiostat MkII is a software controlled 3-electrode potentiostat/Galvanostat for use in general electrochemistry applications. ZRA and Hi Z modes are also available. Current ranges from 20 nA to 100 mA full scale with 16 bit resolution and 12 V compliance. Includes iR compensation. It replaces the EA161 and has extended frequency response to 100 kHz for use with the Z100 EIS system. It supports all EChem methods. Supplied with all necessary cables.
  • EA164
    QuadStat
    Amplifiers & Potentiostats
    EA164 QuadStat contains four software controlled potentiostat channels for use in a number of electrochemistry applications. Current ranges from 10mA to 200pA full scale at up to Ă_x0082_Âą10 V with 12V compliance. It supports all EChem methods (on a single channel only). Supplied with all necessary cables.
  • EA165
    Potentiostat EA165
    Amplifiers & Potentiostats
    The EA165 Potentiostat MkII is a software controlled 3/4-electrode potentiostat/Galvanostat for use in general electrochemistry applications. ZRA and Hi Z modes are also available. Current ranges from 20 nA to 200 mA full scale with 16 bit resolution and 12 V compliance. Includes iR compensation. It replaces the EA163 and has extended frequency response to 100 kHz for use with the Z100 EIS system. It supports all EChem methods. Supplied with all necessary cables.
  • EA167
    Dual Reference Adaptor
    Amplifiers & Potentiostats
    The ER167 Dual Reference Adapter is connected to the reference electrode lead of a three-electrode potentiostat (e.g. EA160, EA161, EA163, ER466) so that two reference electrodes can be used. Typically used for trans-membrane electrochemistry experiments, or studies across the interface of two immiscible liquids, where a 4-electrode potentiostat is required.The Unit can also be used as a Stand Alone Hi Z Differential amp
  • EA362
    Dual PicoStat EA362
    Amplifiers & Potentiostats
    The EA362 Dual Picostat is a galvanically isolated, software controlled high sensitivity potentiostat featuring: single 3-electrode potentiostat mode (RE, AE, and WE) dual 3-electrode mode (two each of RE, AE and WE) bipotentiostat mode (RE, WE, and two WE) 4-electrode mode (two RE and two WE) for use in electrochemistry or neurophysiology. Current ranges from 20 pA to 100 uA full scale and 12 V compliance. It supports all EChem methods. Supplied with all necessary cables and a mains powered 12 volt power pack.
  • EA910
    Set of 12 open top caps with silicon liner for V-vials
    Accessories
    Set of 12 open top caps with silicon liner for V-vials
  • EC001-4
    BNC to BNC Cables (1 m)
    Cables and Connectors
    Pack of Four, fully moulded BNC to BNC cable. Length: 1m
  • EC002
    Cable, DB9M to DB9F - 350mm long
    Cables and Connectors
    A 9 pin D-type male to 9 pin D-type female cable, supplied with all eDAQ Amps. For connecting the I2C control port of an eDAQ Amp to the I2C port of an e-corder. It can also be used for making a 'daisy chain' of multiple Amps.
  • EC004
    Cable, BNC to 4 mm Banana Plug
    Cables and Connectors
    BNC to dual 4 mm Banana Plug Cable (3m long).
  • EC005
    Cable, BNC to BNC 2m)
    Cables and Connectors
    Fully moulded BNC to BNC cable, 1m long. For connecting eDAQ Amps or other devices with a BNC output to an e-corder unit.
  • EC006
    Cable, US Mains Power
    Cables and Connectors
    Cable, US Mains Power1.8M IEC
  • EC007
    Cable, Set of two cables, BNC to Alligator Clip (Red, Green)
    Cables and Connectors
    Pair of cables, BNC to Alligator Clip. Yellow / Black. Used with ER167 Dual reference Adapter.
  • EC008
    BNC to Pair of Alligator Clips
    Cables and Connectors
    Cable, BNC to pair of Alligator Clips 750 mm Long
  • EC009
    BNC Male to 4 mm Banana Plug Adapter
    Cables and Connectors
    BNC to 4 mm Banana Plug adapter used to connect individual conductors to a BNC connection.
  • EC010
    BNC T piece
    Cables and Connectors
    BNC T-piece for splitting a signal.
  • EC011
    Cable, 4mm Banana Plug to 4mm Banana Plug, Green 700mm long
    Cables and Connectors
    4 mm to 4 mm green banana plug non-stackable cable 700 mm long. Used to connect two system grounds.
  • EC012
    Cable, 4mm Banana Plug to Alligator with 2mm Stackable Plugs
    Cables and Connectors
    Green 4 mm plug to 2 mm Green Plug terminated with a Green Alligator clip - 750 mm Long. Used to ground transducer shield.
  • EC013
    Cable, European Mains Power
    Cables and Connectors
    Cable, European Mains Power1.8M IEC
  • EC014
    Cable, 4mm Banana Plug to 2mm Plug, Alligator Clip, RED (PACK of 4)
    Cables and Connectors
    PACK of 4 cables. Each cable consists of a RED 4 mm plug at one end of a 750 mm long thin flexible cable and a 2 mm stackable RED plug terminated with a RED Alligator clip.
  • EC015
    Cable, Chip holder Ground Cable, Green
    Cables and Connectors
    Green 4mm plug to 2mm Green Plug - 750mm Long.
  • EC016
    Cable, BNC to BNC (6 m)
    Cables and Connectors
    BNC to BNC cable, length 6m.
  • EC017
    Cable, Stackable 4mm Banana Plug to Stackable 4mm Banana Plug, Green 450mm long
    Cables and Connectors
    4 mm to 4 mm green banana plug non-stackable cable 450 mm long
  • EC018
    Cable, Stackable 4mm Banana Plug to Stackable 4mm Banana Plug, Green 1000mm long
    Cables and Connectors
    4 mm to 4 mm green banana plug non-stackable cable 1 m long
  • EC019
    Cable, Australian Mains Power
    Cables and Connectors
    Cable, Australian Mains Power1.8M IEC
  • EC020
    C4D 3 Ion Standard
    Accessories
    EC20 is a set of 2 sealed sterilized ampoules containing a 0.5M acetic acid buffer and a 1mM solution of each of lithium, sodium, potassium, chloride, nitrate, and sulphate ions in deionised water. Individual Test certificates provided by Absolute Standards Inc.
  • EC023
    PACK OF O RINGs FOR UCHIP HOLDER
    Accessories
    3MM 1MM O RING PACK OF 10 (For ET225 UCHIP HOLDER)
  • EC024
    PACK OF O RINGs FOR ET014
    Accessories
    #001 Qty 2#003 Qty1#004 Qty 1#006 Qty 1
  • EC025
    20 POS Instrument Connection Port Adapter Pack
    Accessories
    Pheonix Contact Mini Combican Instrument Connection Port Adapter. Green Plug component, nominal current: 8 A, rated voltage: 160 V, pitch: 3.5 mm, no. of positions: 20, type of connection: Screw connection. Used in QuadStat, PowerPhrom.and other eDAQ products.
  • EC025
    20 POS Instrument Connection Port Adapter Pack
    Cables and Connectors
    Pheonix Contact Mini Combican Instrument Connection Port Adapter. Green Plug component, nominal current: 8 A, rated voltage: 160 V, pitch: 3.5 mm, no. of positions: 20, type of connection: Screw connection. Used in QuadStat, PowerPhrom.and other eDAQ products.
  • EC026
    Cable, UK Mains Power
    Cables and Connectors
    Cable, UK Mains Power1.8M IEC
  • EC028
    Cable adapter 8 Way Lemo to 8 Way Female DIN.
    Cables and Connectors
    Lemo to DIN Adapter Short adapter cable connecting the EA010 input to e corder 8 way DIN socket.suitable for pod connections and General purpose use
  • EC032
    Cable, DB9M to DB9F - 1.8m long
    Cables and Connectors
    A 9 pin D-type male to 9 pin D-type female cable, supplied with all eDAQ Amps. For connecting the I2C control port of an eDAQ Amp to the I2C port of an e-corder. It can also be used for making a 'daisy chain' of multiple Amps.
  • EC051
    Cable, BNC to Alligator with 2mm stackable plugs, GREEN, (PACK of 4)
    Cables and Connectors
    PACK of 4 cables. Each cable consists of a BNC plug at one end of a 750 mm long thin coax cable and a 2 mm stackable Green plug terminated with a Green Alligator clip. Used with EA164 QuadStat.
  • EC052
    Cable, BNC to Alligator,with 2mm stackable plugs, YELLOW, (PACK of 4)
    Cables and Connectors
    PACK of 4 cables. Each cable consists of a BNC plug at one end of a 750 mm long thin coax cable and a 2 mm stackable yellow plug terminated with a yellow Alligator clip. Used with EA164 QuadStat.
  • EC053
    Cable, BNC to Alligator,with 2mm stackable plugs, BLUE ( PACK OF 4)
    Cables and Connectors
    PACK of 4 cables. Each cable consists of a BNC plug at one end of a 750 mm long thin coax cable and a 2 mm stackable blue plug terminated with a blue Alligator clip.
  • EC054
    Cable, BNC to Alligator,with 2mm stackable plugs, BLUE & Yellow ( PACK OF 2)
    Cables and Connectors
    BNC to stackable 2mm terminal, 2 mm terminals fitted with blue and yallow alligator clips.
  • EC060
    Cable, BNC to Tinned Ends
    Cables and Connectors
    EC060 is BNC to bare tinned ends cable 750 mm long
  • EC071
    Cable, Trigger cable- DB9 male to tinned ends EC071
    Cables and Connectors
    Agilent 7100 trigger cable consisting of a DB9M to Tinned end cable 750 mm long. This cable is also available to connect to ER125 or ER225 systems Trigger. Available to special order only. Also available as a EC072 DB9 to BNC for connection to an e-corder trigger.
  • EC072
    Cable, Agilent 7100 Trigger cable EC072- DB9 male to BNC
    Cables and Connectors
    Agilent 7100 trigger cable consisting of a DB9M to BNC cable 750 mm long for connecting a trigger to an e-corder, Available to special order only. Also available as a EC071 DB9 to Tinned ends for connection to an ER125 or ER225 Trigger.
  • EC073
    Cable, ER815/825 Trigger cable- DB9 Female to BNC
    Cables and Connectors
    Cable, ER815/825 Trigger cable consisting of a DB9F to BNC cable 750 mm long for connecting a ER815/825.
  • EC074
    Cable, Trigger cable- DB9 female to tinned ends EC074
    Cables and Connectors
    Trigger cable consisting of a DB9F to Tinned end cable 750 mm long. Special modification required as per BS instructions. This cable is also available to connect to ER815 or ER825 systems Trigger. Optional trigger cable to be purchased separately with ER815 and ER825 unit.customers options including EC071/EC072/EC073
  • EC091
    Foot Switch
    Accessories
    The foot switch is used as a triggering device. The switch has a normally open contact and when depressed gives contact a closure. It is connected to the trigger input of an e-corder.
  • EC092
    Push Button Switch
    Accessories
    The Push Button switch is used as a triggering device. The switch has a normally open contact and when depressed provides a contact closure. It is connected to the trigger input of an e-corder.
  • EC1208
    Headstage Adapter assembly with 8 pin DIN
    Cables and Connectors
    Headstage Adapter with DIN 8 Way
  • EC1210
    Headstage Adapter assembly with 10 way Lemo
    Cables and Connectors
    Headstage Adapter with Lemo 10 Way
  • EC161
    Cable, Electrode Cable for EA160 Potentiostats
    Cables and Connectors
    Input cable. Provides shielded connection between EA160 and electrochemical cell. 8 Pin DIN cable to 3 alligator clips. Length 750 mm
  • EC162
    Cable, Electrode Cable for Potentiostats
    Cables and Connectors
    Input cable. Provides shielded connection between electrode and the EA161 and EA163 Potentiostats, EA162 Picostat, ER466 Potentiostat, and EA362 Dual Picostat. 6 Pin Lemo to 3 removable alligator clips. Length 850 mm
  • EC163
    Cable, Electrode Cable for Potentiostats-Long
    Cables and Connectors
    Input cable. Provides shielded connection between electrode and the EA161 and EA163 Potentiostats, EA162 Picostat, ER466 Potentiostat, and EA362 Dual Picostat. 6 Pin Lemo to 3 removable alligator clips. Length 1500 mm
  • EC167
    Cable, Electrode Cable for High Current Potentiostats
    Cables and Connectors
    Input cable. Provides shielded connection between electrode and the ER467 / EA165. 8 Pin Lemo to 5 removable alligator clips -Red Yellow green black and blue. Length 850 mm
  • EC201
    Cable,Trigger twin cable with tinned ends
    Cables and Connectors
    EC201 is a bare wire to bare wire cable 750 mm long. Use in some trigger applications
  • EC230
    Cable. EC230-4 HV cable set
    Cables and Connectors
    A set of four different color cables 750 mm long, SHV connector at one end to bare platinum wire termination at the other, to facilitate connection of the ER430 HV Sequencer to an undefined user device. The user must provide suitable high voltage protection and be responsible for safe connections.
  • EC255
    Cable, Differential Pod Input
    Cables and Connectors
    Cable consisting of an 8 pin DIN/Pod connector to three alligator clips. Suitable for connecting a differential or low level signal to the differential input of an e-corder .
  • EC299
    Cable, MicroNit head cable
    Cables and Connectors
    HDMI to Din8 cable assembly.
  • EC400
    Front Panel,Plastic, Small Chassis, Small recess Unpainted
    Cables and Connectors
    None
  • EC401
    Potentiostat Cable kit for EA163 - EA466 - EA162 - EA362
    Cables and Connectors
    EC012 4 mm to 2 mm GREEN cable with Alligator clip EC162 Electrode Cable for Potentiostats - 850mm Long with Alligator clips EC409 3-way BNC to BNC cable. Used with Potentiostat & Picostat
  • EC402
    QuadStat cable Kit
    Cables and Connectors
    EC012 4 mm to 2 mm GREEN cable with Alligator clip EC014 Cable, 4 mm Plug to 2 mm stackable plug with RED Alligator clip, (PACK of 4) EC025 20 POS Instrument Connection Port Adapter Pack EC051 Cable, BNC to Alligator, with 2 mm stackable GREEN plug, (PACK of 4) EC052 Cable, BNC to Alligator, with 2 mm stackable YELLOW plug, (PACK of 4) EC060 Cable, BNC to Tinned ends EC408 4-way BNC to bare wires cable. Length 1.2 m EC408 4-way BNC to bare wires cable. Length 1.2 m
  • EC405
    Cable, USB Cable 2m Moulded Type A-B
    Cables and Connectors
    USB Cable (Type AB) suitable for connecting an e-corder or PowerChrom to a computer.
  • EC406
    USB miniB Cable used by USB isoPods
    Cables and Connectors
    USB Cable (Type A to miniB) suitable for connecting a USB isoPod to a computer or USB hub
  • EC408
    4 Way BNC to Tinned ends
    Cables and Connectors
    4-way BNC to bare wires cable. Length 1.2 m. Two of these cables are supplied with a Quadstat unit
  • EC409
    Cable, BNC to BNC Cable 3 way Colour coded-1000mm long
    Accessories
    3-way BNC to BNC cable. Length 1.5 m. Supplied with EA161 and EA163 Potentiostats and EA162 Picostat.
  • EC409
    Cable, BNC to BNC Cable 3 way Colour coded-1000mm long
    Cables and Connectors
    3-way BNC to BNC cable. Length 1.5 m. Supplied with EA161 and EA163 Potentiostats and EA162 Picostat.
  • EC410
    Reed relay Interlock cable
    Cables and Connectors
    Cable with BNC and reed relay interlock
  • EC412
    Black and Red Alligator Clips (Pack of 5 each)
    Cables and Connectors
    EC080 Black Alligator Clip Qty 5 EC081 Red Alligator Clip Qty 5
  • EC413
    Spare Alligator clips for Potentiostats- Red, Green, Yellow (Qty 5 each)
    Cables and Connectors
    EC081 Red Alligator Clip (5 off) EC082 Green Alligator Clip (5 off) EC083 Yellow Alligator Clip (5 off)
  • EC414
    Yellow and Blue Alligator clips (Qty 5 each)
    Cables and Connectors
    EC083 Yellow Alligator Clip (Qty 5) EC084 Blue Alligator Clip (Qty 5)
  • EC450
    Female BNC to Mini clip adaptor
    Cables and Connectors
    Female BNC to Mini clip adaptor. 1 red and 1 black cable and clips to Female BNC. Nominal 150mm long
  • EC500
    12V AC-DC Desktop Power Supply 60W
    Accessories
    AC to DC external power adapter.Input 100 - 240V ~ 50/60Hz, 0.5AOutput 12V DC 5A 60W Max
  • EC501
    5V AC-DC Desktop Power Supply 5W
    Accessories
    AC to DC external power adapter. Input 100 - 240V ~ 50/60Hz, 1A Output 5V DC 1A 5W Max . Multiple AC plugs for international use. Suitable for use with EPU452 etc.
  • EC794
    ER815-OEM Adapter
    Cables and Connectors
    None
  • EC795
    Cable,ER28 I2C extension IO
    Cables and Connectors
    None
  • ED1621
    e-corder 1621
    Data Acquisition Systems
    e-corder 1621 is a 16 channel, continuous 400,000 s/s throughput 16 bit resolution data acquisition system with programmable gain. Twelve SE + four SE/differential inputs, 8/8 digital I/O, 4 Pod ports and a bipolar DAC output. Supports all eDAQ Amps and Pods. Communicates with PC via the Hi-Speed USB interface. Supplied with Chart and Scope software.
  • ED410
    e-corder 410
    Data Acquisition Systems
    e-corder 410 is a 4 Channel, continuous 100,000 s/s per channel, 24 bit resolution data acquisition system with programmable gain. Four SE/differential inputs , 4 Pod ports, a bipolar DAC output and 8/8 digital I/O. This unit supports all eDAQ Amps and Pods. Communicates with PC via the high speed USB interface. Supplied with Chart and Scope software.
  • ED821
    e-corder 821
    Data Acquisition Systems
    e-corder 821 is an 8 channel, continuous 400,000 s/s throughput, 16 bit resolution data acquisition system with programmable gain. Four SE + 4 SE/differential inputs, 8/8 digital I/O, 4 Pod ports and a bipolar DAC output. Supports all eDAQ Amps and Pods. Communicates with PC via the Hi-Speed USB interface. Supplied with Chart and Scope software.
  • ED832
    Microbial Growth Electronic Analyser Detection Board
    Research Systems
    None
  • EP352
    Biosensor isoPod
    isoPods (Non USB)
    The EP352 isoPod provides an isolated low current to Voltage converter suitable for use with a variety of current sources including 2 electrode amperometric biosensors and photodiodes. Can also be used as a low current ZRA. Baseline offset is provided to allow accurate recording of currents in the 2Ă_x0082_ÂľA to 2nA range.
  • EP353
    Isolated pH/ISE Pod
    isoPods (Non USB)
    The EP353 isoPod provides a simple isolated interface to pH, ISE and Redox Electrodes with BNC input connectors. Also provides Hi Z measuring capability from +/- 200mV to +/-2000mV.
  • EP354
    Isolated dO2 Pod
    isoPods (Non USB)
    The EP354 isoPod provides an isolated interface to a dissolved Oxygen Electrode. Adjustable poise voltage is available to suit the application. Current in the range 20Ă_x0082_ÂľA to 20nA is software selectable. Baseline offset is provided to allow more accurate recording small changes in oxygen concentrations.
  • EP355
    Isolated NO Pod
    isoPods (Non USB)
    The EP355 isoPod provides an isolated interface to NO electrodes. Adjustable poise voltage is available to suit the application. Current in the range 2Ă_x0082_ÂľA to 2nA Full scale can be measured to meet the requirements of most NO electrodes. Baseline offset is provided to allow more accurate recording of small changes in NO concentrations.
  • EP356
    Isolated Thermocouple Pod
    isoPods (Non USB)
    The EP356 isoPod provides a fast accurate universal and NIST polynomial calibrated thermocouple amplifier with Ice Point reference compensation. In the mV mode the system has a full scale range of +/-20mV with Ă_x0082_ÂľV resolution.
  • EP357
    Isolated Conductivity Pod
    isoPods (Non USB)
    The EP357 isoPod provides a wide range of conductivity measurements from 200mS to 2Ă_x0082_ÂľS Full scale with K=1 electrodes. Suitable electrodes include the ET908 Flow-Thru Conductivity Electrode (0.093 ml), ET915 Dip-In Conductivity Electrode, ET916 Flow-Thru Conductivity Electrode (0.017 ml).
  • EP358
    RTD/Thermistor isoPod
    isoPods (Non USB)
    The EP358 isoPod provides an isolated, wide range of temperature measurements using 30K Thermistor probes for 0-70C and a 1000 Ohm RTD for -25-+250C precision measurements. The system is adaptable to other resistive temperature sensors.
  • EPU160
    MMB16 IO Expander
    Interface and Third Party Prod
    This interface allows up to 16 TTL logic, or contact closure, signals to generate user defined comments in Chart using a virtual serial protocol over a USB port. The system is supplied with a Chart extension which allows easy use with e-corder 4, 8 and 16 channel systems. Alternatively the serial protocol can be used by users chosing to write their own software.
  • EPU352
    Biosensor isoPod with USB IO
    USB isoPods
    The EPU352 is a USB based isoPod providing an isolated low current to Voltage converter suitable for use with a variety of current sources including 2 electrode amperometric biosensors and photodiodes. Baseline offset is provided to allow accurate recording of currents in the 2Ă_x0082_ÂľA to 2nA range. Supported by a serial protocol.
  • EPU353
    Isolated pH/ISE Pod with USB IO
    USB isoPods
    The EPU353 isoPod provides a simple USB based isolated interface to pH, ISE and Redox Electrodes with BNC input connectors. Also provides Hi Z measuring capability from +/- 200mV and+/-2000mV. Supported by a serial protocol.
  • EPU354
    Isolated dO2 Pod with USB IO
    USB isoPods
    The EPU354 is a USB based isoPod providing an isolated interface to a dissolved Oxygen Electrode. Adjustable poise voltage is available to suit the application. Current in the range 20Ă_x0082_ÂľA to 20nA is software selectable. Baseline offset is provided to allow more accurate recording small changes in oxygen concentrations. Supported by a serial protocol.
  • EPU355
    Isolated NO2 Pod with USB IO
    USB isoPods
    The EPU355 is a USB based isoPod providing an isolated interface to NO electrodes. Adjustable poise voltage is available to suit the application. Current in the range 2Ă_x0082_ÂľA to 2nA Full scale can be measured to meet the requirements of most NO electrodes. Baseline offset is provided to allow more accurate recording of small changes in NO concentrations. Supported by a serial protocol.
  • EPU356
    Isolated Thermocouple Pod with USB IO
    USB isoPods
    The EPU356 is a USB based isoPod providing a fast accurate universal and NIST polynomial calibrated thermocouple amplifier with Ice Point reference compensation. In the mV mode the system has a full scale range of +/-20mV with Ă_x0082_ÂľV resolution. Supported by a serial protocol.
  • EPU357
    Isolated Conductivity Pod with USB IO
    USB isoPods
    The EPU357 is a USB based isoPod providing a wide range of conductivity measurements from 200mS to 2Ă_x0082_ÂľS Full scale with K=1 electrodes. Suitable electrodes include the ET908 Flow-Thru Conductivity Electrode (0.093 ml), ET915 Dip-In Conductivity Electrode, ET916 Flow-Thru Conductivity Electrode (0.017 ml). Supported by a serial protocol.
  • EPU358
    RTD/Thermistor isoPod with USB IO
    USB isoPods
    The EPU358 is a USB based isoPod providing an isolated interface providing a wide range of temperature measurements using 30K Thermistor probes for 0-70C and a 1000 Ohm RTD for -25 to+250C precision measurements. The system is adaptable to other resistive temperature sensors.
  • EPU452
    Quad MF isoPod. Supports multiple sensor types. With USB connection.
    USB isoPods
    The EPU452 provides 4 individually isolated channels. Each channel can have an independently selectable function set by software: dO2/Amperometric Biosensor pH/ISE/ORP/HiZ mV Temperature (Thermistor 0-70C or RTD -25- +250C) Conductivity. The unit is powered and communicates directly via the USB bus. 20 - 24 bit ADC precision and 0.1% accuracy is provided. Supported by a serial protocol and includes a Pod-Vu License.
  • ER175
    Waveform Generator
    Research Systems
    The ER175 is a programmable waveform generator designed to produce cyclic voltammetry waveforms capable of being controlled by user manual intervention. System can be programmed to produce other waveforms. Programmable trigger and digital input/output functions allow the system to control external recorders.
  • ER175
    Waveform Generator
    End of Life
    The ER175 is a programmable waveform generator designed to produce cyclic voltammetry waveforms capable of being controlled by user manual intervention. System can be programmed to produce other waveforms. Programmable trigger and digital input/output functions allow the system to control external recorders.
  • ER180C
    Two Channel Mini-corder with Chart software
    Data Acquisition Systems
    The ER180C is a dual channel data recording system. It consists of a hardware unit providing 24 bit resolution- 10 mV - 10V FS and sampling rates up to 1000/s. A single contact closure/TTL input is provided for trigger function and also Four Digital Output Contact closures. Communicates with PC via fast USB. Supplied with ES500 Chart and Scope software providing advanced recording and analysis capability. A suitable Trigger cable, if required , must be ordered separately.
  • ER180F
    Two Channel Flow Injection Analysis System
    Research Systems
    The ER180F is a dual channel Flow Injection Analyis data system. It consists of a hardware unit providing 24 bit resolution- 10 mV - 10V FS and sampling rates up to 1000/s. A single contact closure/TTL input is provided for trigger function. Communicates with PC via fast USB. Provided with ES500 Chart software with FIA and Event Manager extensions. Trigger cable, if required , must be ordered separately..
  • ER180R
    Two Channel PowerChrom Chromatography Data System
    Research Systems
    The ER180R is a dual channel chromatography data system. It consists of a hardware unit providing 24 bit resolution- 10 mV - 10V FS and sampling rates up to 100/s. A single contact closure/TTL input is provided for trigger function and also Four Digital Output Contact closures. Communicates with PC via fast USB. Supplied with PowerChrom software for recording and analysis of Chromatogrpahy data. Trigger cable, if required , must be ordered separately.
  • ER181C
    One channel Mini-corder with Chart Software
    Data Acquisition Systems
    The ER181C is a single channel data recording system. It consists of a hardware unit providing 24 bit resolution- 10 mV - 10V FS and sampling rates up to 2000/s. A single contact closure/TTL input is provided for trigger function. Communicates with PC via fast USB. Supplied with Chart and Scope software for recording and analysis of experimental data.
  • ER181F
    One Channel Flow Injection Analysis System
    Research Systems
    The ER181F is a single channel Flow Injection Analysis data system. It consists of a hardware unit providing 24 bit resolution- 10 mV - 10V FS and sampling rates up to 100/s. A single contact closure/TTL input is provided for trigger function. Communicates with PC via fast USB. Provided with ES500 Chart software with FIA and Event Manager extensions.
  • ER181R
    One Channel PowerChrom Chromatography Data System
    Research Systems
    The ER181R is a single channel chromatography data system. It consists of a hardware unit providing 24 bit resolution- 10 mV - 10V FS and sampling rates up to 100/s. A single contact closure/TTL input is provided for trigger function.. Communicates with PC via fast USB. Supplied with PowerChrom software for recording and analysis of Chromatography data. Trigger cable, if required , must be ordered separately.
  • ER181RE
    One Channel PowerChrom Chromatography Data System NTS EasyChrome software
    Research Systems
    The ER181RE is a single channel chromatography data system. It consists of a hardware unit providing 24 bit resolution- 10 mV - 10V FS and sampling rates up to 100/s. A single contact closure/TTL input is provided for trigger function.. Communicates with PC via fast USB. Supplied with NTS EasyChrome software for recording and analysis of Chromatography data- Latest version to be downloaded.https://drive.google.com/file/d/1PBDQy4Gv-D_8TxEhoKakTpIX6xKNeAsL/view?usp=sharing PowerChrom license code included- Generate NEW license code Trigger cable, if required , must be ordered separately.
  • ER225
    C4D Data System
    Research Systems
    ER225 is a complete C4D system consisting of a C4D amplifier (similar to the EA120) and a PowerChrom data system. Head stage excitation frequencies in the range 50kHz to 2MHz and 1V to 100Vpp amplitudes can be selected under computer control thus providing a wide dynamic range of conductivity measurements. Background conductivity can be offset to provide better resolution peak data. Requires suitable head stage.
  • ER225B
    C4D Data System - DC variant
    Research Systems
    The ER225B is a complete C4D system (see ER225 for detail) provided with a 9-16 volt input power capability compatible with 12 volt batteries and AC to 12VDC power packs. It is suitable for field use if protected against weather. A suitable universal AC power pack is provided. The mains filter is not implemented. Suitable head stage must be ordered separately.
  • ER280
    PowerChrom 280 System
    Research Systems
    PowerChrom 280 is a 2 channel chromatography data system. It consists of data analysis and control software together with a hardware unit providing from 24 bit resolution, 20 mV - 10V FS and sampling rates up to 100/s. Four contact closure/TTL outputs and a single contact closure/TTL input are provided for control functions. Supplied with Windows XP & Vista compatible PowerChrom software. Communicates with PC via fast USB.
  • ER280B
    PowerChrom 280 System - DC Power version
    Research Systems
    The ER280B is a PowerChrom system (see ER280 for detail) provided with 9-16 volt input power compatible with 12 volt batteries and AC to 12VDC power packs. It is suitable for field use if protected against weather. A suitable universal AC power pack is provided. The mains filter is not implemented.
  • ER282
    Flow Injection Analysis System
    Research Systems
    A ER282 is a 2 channel Flow Injection recording, control and analysis system. It consists of a PowerChrom ER280 hardware unit with Chart software together with the Flow Injection Analysis and Event manager software extensions. Communicates with PC via fast USB. Supplied with Chart software.
  • ER282K
    Flow Injection Analysis
    Research Systems
    A ER282 is a 2 channel Flow Injection recording, control and analysis system. It consists of a PowerChrom ER280 hardware unit with Chart software together with the Flow Injection Analysis and Event manager software extensions. Communicates with PC via fast USB. Supplied with Chart software.
  • ER430
    HV Sequencer - Quad HV supply for microfluidic chips.
    Research Systems
    The ER430 HV Sequencer is a system that provides four user programmable +/- 3 kV @100uA supplies. Each output can also be configured as voltage or current meters. Software is provided that controls the application of voltages in the sequence required to perform the experiment via an e-corder or independent USB connection.
  • ER455K
    ER455 Microchip Electrophoresis Kit
    Kits and Bundles
    The ER455K provides a complete Microchip Capillary Electrophoresis system consisting of an ER225, ER430 Quad High Voltage sequencer, EC020 Standards Test solutions, ET225 MCE platform and either ET145-4 or ET190-2 microchips (Please specify).
  • ER461K
    EChem Startup System, includes ER466, ES500, ES260, ET014
    Kits and Bundles
    The ER461K is a complete electrochemistry laboratory consisting of a ER466C combination recorder and potentiostat, Chart, Scope and EChem Software, and an ET014 EChem Electrode kit.
  • ER466C
    Integrated Potentiostat System - includes Chart and Scope software
    Research Systems
    ER466C is a potentiostat system consisting of a 4 Channel e-corder system and an EA163 functionally equivalent potentiostat with some enhancements such as OCP function. In addition to current and potential recording channels two general purpose input channels (and matching Pod ports) are provided for ancillary measurements. Supplied with Chart and Scope software. Trigger cable, if required , must be ordered separately.
  • ER466CE
    Integrated Potentiostat System - includes Chart, Scope and Echem software
    Research Systems
    ER466CE is a potentiostat system consisting of a 4 Channel e-corder system and an EA163 functionally equivalent potentiostat with some enhancements such as OCP function. In addition to current and potential recording channels two general purpose input channels (and matching Pod ports) are provided for ancillary measurements. Supplied with Chart, Scope and EChem software. Trigger cable, if required , must be ordered separately.
  • ER466E
    Integrated Potentiostat System - includes EChem software
    Research Systems
    ER466C is a potentiostat system consisting of a 4 Channel e-corder system and an EA163 functionally equivalent potentiostat with some enhancements such as OCP function. In addition to current and potential recording channels two general purpose input channels (and matching Pod ports) are provided for ancillary measurements. Supplied with EChem software. Trigger cable, if required , must be ordered separately.
  • ER467C
    High Current Potentiostat- includes Chart and Scope software
    Research Systems
    ER466C is a High Current Potentiostat consisting of a 4 Channel e-corder system and a 1 AMP potentiostat with some enhancements such as OCP function. In addition to current and potential recording channels two general purpose input channels and matching Pod ports are provided for ancillary measurements. Supplied with Chart and Scope software.
  • ER467CE
    High Current Potentiostat- includes Chart, Scope and EChem software
    Research Systems
    ER466CE is a High Current Potentiostat consisting of a 4 Channel e-corder system and a 1 AMP potentiostat with some enhancements such as OCP function. In addition to current and potential recording channels two general purpose input channels and matching Pod ports are provided for ancillary measurements. Supplied with Chart, Scope and Echem software.
  • ER467E
    High Current Potentiostat- includes EChem software
    Research Systems
    ER466C is a High Current Potentiostat consisting of a 4 Channel e-corder system and a 1 AMP potentiostat with some enhancements such as OCP function. In addition to current and potential recording channels two general purpose input channels and matching Pod ports are provided for ancillary measurements. Supplied with EChem software.
  • ER490
    ER490 Microchip electrophoresis experiments system
    Kits and Bundles
    The ER490 kit includes: ER815R C4D Detector with PowerChrom software, ER430 High Voltage Sequencer, EC230 High Voltage Cables, ET121 Microchip Platform with C4D Electrodes including two ET195-2 Zeonor Chips, EC020 Standard Test Solution, ET067 Lead Wire Clamp
  • ER7004
    Mega Teaching Kit
    Kits and Bundles
    The ER7004 eDAQ Mega teaching kit provides a broad range of hardware and software to replace expensive, single purpose analytical instruments and provides the means to implement interesting and dynamic learning opportunities in analytical chemistry. The kit contains:ER466 Integrated potentiostat, ET014 Electrode Kit, EP353 pH isoPod, ET5733 pH electrode, ET060 Redox Electrode, EP354 dO2 isoPod, ET1117 Oxygen electrode, EP356,Thermocouple isoPod, ET1400 T-Type Thermocouple probe, EP357 Conductivity isoPod, ET902 Conductivity probe, ET226 Drop Counter, ET1010 Pulse transducer, ET079-1 Copper disc Voltametric electrode, ET325 Thin Film Solar Cell. Chart, Scope, Echem and PowerChrom software.
  • ER7006
    MultiSensor Teaching Kit
    Kits and Bundles
    This Multi Sensor Teaching Kit contains a EPU452 Quad MF isoPod and Pod-Vu software together with a set of commonly used sensors/electrodes used to measure pH,ISE, temperature, conductivity, dissolved oxygen, voltage and amperometric sensors etc. ET5733 Combination pH Electrode - Tuff tip for student use. ET060 ORP Electrode. Combination type - has internal reference. ET902 Conductivity Cell, k=1, 12 mm diameter glass body ET021 RTD Temperature Probe EC008 BNC to Pair of Alligator Clips REMOVED OCT 22 ET1117 Polarographic Oxygen Electrode- REMOVED OCT 22
  • ER7070
    2 CH C4D Detector with headstage, Serial Protocol software and Trigger cable.
    Kits and Bundles
    The ER7070 OEM kit consists of the following components: ER815-OEM detector PCB, ET120 headstage, Serial protocol software and an EC074orEC073 Trigger cable. Final PCB configuration to be confirmed.
  • ER7070C
    2 CH Contactless Conductivity Detector with head stage, Chart software and Trigger cable.
    Kits and Bundles
    The ER7070C OEM kit consists of the following components: ER815-OEM detector PCB, ET120 headstage, ES500 Chart software and an EC074 Trigger cable. Final PCB configuration to be confirmed.
  • ER7070R
    2 CH C4D Detector with head stage, PowerChrom software and Trigger cable.
    Kits and Bundles
    The ER7070R OEM kit consists of the following components: ER815-OEM detector PCB, ET120 headstage, ES280 PowerChrom software and an EC074 Trigger cable. Final PCB configuration to be confirmed.
  • ER7162
    Dual PicoStat Bundle
    Kits and Bundles
    This is a Dual PicoStat bundle consisting of an ED410, EA362, ET014 and ES260
  • ER7303
    Standalone Potentiostat for CV applications
    Kits and Bundles
    REPLACED BY ER466E
  • ER815
    Single channel C4D Detector
    Research Systems
    The ER815 Single channel C4D detector consists of a motherboard which supports 1 Input adaptor and head stage. It provides a selectable excitation signal in the range of 10kHz to 2MHz- and a low noise precision(22bit) detection signal processing. The system can output head stage data in analog form to a suitable e-corder (up to 8 channels) or PowerChrom unit (up to 2 channels) or customer data system. Serial data is also available on the USB port. Standard ER815 unit comes complete with 1 head stage adapters (EA025 ).
  • ER815-OEM
    C4D Detector System
    Research Systems
    C4D Detector System. A Two channel C4D detector with a C4D input and general purpose input. This pba is in a small format suitable for mounting inside a oem system
  • ER815-OEMC
    ER815-OEM plus chart
    Research Systems
    Er815-OEM with chart licence and e-corder firmware
  • ER815C
    Contactless Conductivity Detector with Chart - optional Trigger cable available
    Research Systems
    The ER815C is a single channel C4D detector/monitor supporting a single head stage (not included). It provides all required excitation signals to control a compatible head stage. Chart software is supplied to allow monitoring, recording and analysis of C4D data. Standard ER815C unit includes 1 (one) headstage adapter module (EA025). A suitable headstage and Trigger cable (if required) must be ordered separately.
  • ER815R
    Contactless Conductivity Detector with PowerChrom optional Trigger cable available
    Research Systems
    The ER815R is a single channel C4D Chromatography detector and data system supporting a single head stage (not included). It provides all required excitation signals to control a compatible headstage. PowerChrom software is supplied to allow monitoring, recording and analysis of C4D peak data. Standard ER815R unit includes 1 (one) headstage adapter module (EA025). A suitable head stage and Trigger cable (if required) must be ordered separately.
  • ER818
    Octal Contactless Conductivity System
    Kits and Bundles
    The ER818 system was developed to enable the measurement of conductivity in samples with the following general characteristics: Low Sample Volumes, Low Sample Wastage, Zero Cross contamination, 100ÂľS/cm to 20,000 ÂľS/cm conductivity range suitable for operation in an automated system. The system consists of a Control unit (ER815) which provides an interface between a controlling PC and a suitable ET128 Octal headstage which is included with the system. Serial protocol is provided to control the unit and to acquire data at up to 1 scan of 8 channels per second. Control and communication between the ER818 system and the controlling PC is the responsibility of the Customer. A suitable Trigger cable, if required must be ordered separately.
  • ER825
    Multi Channel C4D Detector (Base unit only)
    Research Systems
    The ER825 Multi Channel C4D detector consists of a motherboard which supports from 1 to 8 Input modules( must be ordered seperately) and a combination of heads stages and auxiliary inputs. It provides an selectable excitation signal in the range of 10kHz to 2MHz, and a low noise precision(22bit) detection signal processing. The system can output head stage data in analog form to a suitable e-corder (up to 8 channels) or PowerChrom unit (up to 2 channels) or customer data system. Serial data is also available on the USB port. Each includes a EA025 Input module. ( Additional channels EA025 must be added at time of order)
  • ER825C
    Multi-Channel Contactless Conductivity Detector with Chart. Optional Trigger cable and input card available
    Research Systems
    The ER825C Multi Channel workstation supports from 1 to 8 Input modules, including EA025 and EA010 modules, to measure C4D and general purpose physical quantities. Each active channel requires an EA025 or an EA010 module (none fitted in basic unit). Chart Software is supplied with this system to provide recording and analysis functions at up to 400 samples per second/channel. A suitable C4D head stages and Trigger cable if required must be ordered separately.
  • ER825R
    Two Ch (GP and C4D)Contactless Conductivity Detector with PowerChrom. Optional ch modules available
    Research Systems
    The ER825R Multi Channel workstation fitted with one EA025 and one EA010 module.. PowerChrom software (ES280) is supplied with this system to provide recording, analysis and peak detection functions on up to 2 channels. A suitable C4D headstages and Trigger cable if required must be ordered separately. Each includes a EA025 and EA010 Input module. ( Additional channels EA025 must be added at time of order)
  • ER832-16
    Microbial Growth Electronic Analyser-16 ch
    Research Systems
    Microbial Growth Electronic Analyser 16 channel
  • ER832-32
    Microbial Growth Electronic Analyser-32 ch
    Research Systems
    Microbial Growth Electronic Analyser 32 channel
  • ES017
    Ecorder firmware for C4D system
    Software, Documentation, Warra
    This firmware provides E-corder functions for ER-815 or ER-825 C4D systems.This will allow the Er8x5 series devices to operate with Powerchrom or Chart software( ordered separately). N.b Provides support for 2Ch max, must be installed at factory and ordered with C4D system.
  • ES260
    EChem Software Installer licence
    Software, Documentation, Warra
    ES260 EChem Software V2.x- Single user License and documentation. EChem is an electrochemistry data system which supports common electrochemical methods. Supports 100,000 s/s sampling rate and 16 bit resolution. It operates with the EA160 Potentiostat, EA162 Picostat as well as most customer supplied (analog driven) external Potentiostats. Latest version of software to be downloaded from eDAQ website. PowerChrom Licence to be supplied
  • ES261
    EChem Software - Departmental License
    Software, Documentation, Warra
    EChem Software - Departmental License. Provides full set of software and documentation on USB together with a license to copy the software to other computers within a single department.
  • ES280
    PowerChrom Software
    Software, Documentation, Warra
    PowerChrom v2.5 software is an advanced acquisition- analysis- control and reporting system for chromatography applications. Latest software to be downloaded from eDAQ website. PowerChrom licence to be supplied
  • ES281
    PowerChrom Software - Departmental License
    Software, Documentation, Warra
    PowerChrom Software - Departmental License. Provides software and electronic documentation together with a license to copy the software to other computers within a single department.
  • ES282
    Flow Injection Analysis System Software Licence
    Software, Documentation, Warra
    Flow Injection Analysis System Software to be downloaded from eDAQ wesite. FIA software licence to be supplied.
  • ES350
    Pod-Vu Software Licence
    Software, Documentation, Warra
    Pod-Vu software collects and displays signals from up to eight USB isoPod channels. Software license code printed on A6
  • ES500
    Chart & Scope Software Licence
    Software, Documentation, Warra
    4 Channel Chart /Scope latest software is downloaded from eDAQ webiste for 2 and 4 channel e-corder systems. Chart provides multichannel, scrolling, continuous chart recording with powerful on-line computing and post-processing analysis functions. Scope provides 2 and 4 channel storage oscilloscope function with analysis.
  • ET014
    EChem Electrode Kit
    Accessories
    The ET014 EChem Electrode Kit contains PEEK encased gold, platinum and glassy carbon working electrodes, 3 mm OD, 1 mm active surface diameter; leakless Ag/AgCl reference electrode, 2 mm OD; platinum coated auxiliary electrode, 1.6 mm OD; and two 3 mL reaction vials with stand.
  • ET021
    1000 ohm Platinum RTD Temperature Probe
    Transducers
    High Accuracy 1000 ohm Platinum RTD Temperature Probe inside a cylindrical stainless steel casing 5 mm OD. Grade AA sensor (formerly Grade 1/3 DIN). Used with EP358 isoPod
  • ET030
    Electrode Polishing Kit
    Accessories
    The ET030 Electrode Polishing Kit contains Glass Plates with rubber feet x 2Polishing Pads x 2 pkts0.30um Alumina Polishx 10.05um Alumina Polishx 1
  • ET031
    Glass plate with feet
    Accessories
    85mm square glass plate, 6mm deep. Arrissed ( rough polished )edges. Fitted with rubber feet
  • ET031-2
    Pair of ET031 glass plates with feet
    Accessories
    Pair of ET031 glass plates with feet
  • ET032
    Polishing Cloth - Pack of 10
    Accessories
    Pack of 10: MICROPAD 2 Polishing Cloth (2 7/8 inch dia)
  • ET033
    0.05 um alumina Powder
    Accessories
    NANO-1005-06 (0.05 um alumina slurry, 6 oz) 0.05 um alumina Powder Net 65gms
  • ET034
    0.3 um alumina Powder
    Accessories
    NANO-1003-06 (0.3 um alumina slurry, 6 oz) 0.3 um alumina Powder - Net 100gms
  • ET042
    pH Electrode. Combination type - has internal reference.
    Transducers
    The ET042 pH Electrode is a Sealed Gel Double Junction electrode suitable for operation from 0-60C, pH range 0-14 pH. Double junction, Cable length 1m standard (Max 20m length Custom order, Connector BNC, Polypropylene Body, easily cleaned and suitable for low ionic strength or messy samples. Requires a EP353 pH isoPod.
  • ET044
    Flow Through pH electrode
    Transducers
    A flow through pH electrode, for use with the EPU353 pH/ISE isoPod, EPU452 Quad Multifunction Isopod or EU168 Quad pH isopod. It has an internal volume of 0.8 ÂľL and connects to 3.2 mm ID tubing. Suitable for small volumes of biological fluids or similar aqueous solutions. Range of measurement is pH0 - 14 with proper calibration and flow control.
  • ET051
    3 mm Glassy carbon disk electrode in PEEK body, 6 mm OD
    Transducers
    3 mm Glassy carbon disk electrode in PEEK body, 6 mm OD
  • ET051-3
    3 Pack ET051, 3 mm Glassy carbon disk electrode in PEEK body, 6 mm OD
    Transducers
    Three pack of ET051, 3 mm Glassy carbon disk electrode in PEEK body, 6 mm OD
  • ET052
    3 mm Platinum disk electrode in PEEK body, 6 mm OD
    Transducers
    3 mm Platinum disk electrode in PEEK body, 6 mm OD
  • ET052-3
    3 Pack ET052, 3 mm Platinum disk electrode in PEEK body, 6 mm OD
    Transducers
    Three pack of ET052, 3 mm Platinum disk electrode in PEEK body, 6 mm OD
  • ET053
    3 mm gold disk electrode in PEEK body, 6 mm OD
    Transducers
    3 mm gold disk electrode in PEEK body, 6 mm OD
  • ET053-3
    3 Pack ET053,3 mm Gold disk electrode in PEEK body, 6 mm OD
    Transducers
    Three pack of ET053, 3 mm Gold disk electrode in PEEK body, 6 mm OD
  • ET054
    Ag/AgCl Refillable reference electrode, 6 mm OD
    Transducers
    Ag/AgCl Refillable reference electrode, 6 mm OD
  • ET054-3
    3 Pack ET054 -Ag/AgCl Refillable reference electrode, 6 mm OD
    Transducers
    Three pack of ET054, Ag/AgCl reference electrode, 6 mm OD
  • ET055
    Platinum plate electrode (6.5 x 6.5 mm square) with glass body
    Transducers
    Platinum plate electrode (6.5 x 6.5 mm square) with glass body
  • ET055-3
    3 Pack ET055, Platinum plate electrode (6.5 x 6.5 mm square) with glass body
    Transducers
    Three pack of ET055, Platinum plate electrode (6.5 x 6.5 mm square) with glass body
  • ET056
    3 mm Copper disk electrode in PEEK body, 6 mm OD
    Transducers
    None
  • ET056-3
    3 Pack ET056,
    Transducers
    None
  • ET057
    3 mm Silver disk electrode in PEEK body, 6 mm OD
    Transducers
    None
  • ET057-3
    3 Pack ET057
    Transducers
    None
  • ET060
    ORP Electrode. Combination type - has internal reference.
    Transducers
    The ET060 Combination ORP Electrode is suitable for operation from 0-60 C. Double junction, easily cleaned, suitable for messy or biological samples. Requires a EP353 isoPod.
  • ET066
    Flow cell for Zensor screen printed electrodes
    Transducers
    Flow cell for Zensor screen printed electrodes, especially ET083-40. Supplied with reference electrode and auxiliary electrode.
  • ET067
    Clamp for potentiostat electrode leads - Helping Hands
    Accessories
    Clamp for potentiostat electrode leads. Also supplied as a part of ET014 electrode kit
  • ET068
    Cell holder for ET080 V-vial electrochemistry vessels
    Accessories
    This holds ET080 V-vial electrochemistry vessels upright. It is included in the ET014 electrode kit.
  • ET069-1
    Leakless Reference Electrode. 5mm Dia, O/A length 130mm
    Transducers
    Leakless Reference Electrode. 5mm Dia, O/A length 130mm
  • ET069-3
    .Leakless Reference Electrode. 5mm Dia, O/A length 130mm, Pack of 3
    Transducers
    Leakless Reference Electrode. 55mm Dia, O/A length 130mm, Pack of 3
  • ET070
    Hydrogen Reference electrode with 1 cartridge, wrench & allen key
    Transducers
    The ET070 is a modern Hydrogen Electrode with integrated hydrogen source making for convenient and safe operation. The hydrogen source is an easily replaceable cartridge with a typical lifetime of 6 months. Comes with 1 hydrogen cartridge. Supplied with Allen key to set hydrogen release rate, and hex spanner for cartridge replacement.
  • ET071
    Set of 4 refill cartridges for ET070
    Transducers
    Gaskatel C 1/2 Refill Cartridge. pack of 4
  • ET072
    Leakless Ag/AgCl Miniature Reference Electrode. 2 mm OD
    Transducers
    Leakless Ag/AgCl Reference Electrode. Suitable for use in organic solvents. 2 mm OD x 45 mm barrel, 65 mm TOTAL length including strain relief and 1 mm pin connector.
  • ET072-3
    Pack of 3. Leakless Ag/AgCl Miniature Reference Electrode. 2 mm OD
    Transducers
    Kit of three: Leakless Ag/AgCl Reference Electrode. Suitable for use in organic solvents. 2 mm OD x 65 mm length.
  • ET072SP
    Customised Leak free electrode - Refer to notes for size
    Transducers
    None
  • ET073
    Refillable Ag/AgCl Miniature Reference Electrode. 2.2 mm OD
    Transducers
    Refillable Ag/AgCl Miniature Reference Electrode. 2.2 mm OD.
  • ET073-3
    Pack of 3- ET073 Refillable Ag/AgCl Miniature Reference Electrode. 2.2 mm OD.
    Transducers
    Kit of three ET073 Refillable Reference electrodes
  • ET074
    Glassy Carbon voltammetric 1mm disk, 3 mm OD, PEEK body electrode
    Transducers
    Glassy Carbon voltammetric electrode. 3 mm OD, PEEK body. 1 mm diameter disk,
  • ET074-3
    Pack of 3: Glassy Carbon voltammetric disk electrode
    Transducers
    Pack of 3: Glassy Carbon voltammetric disk electrode
  • ET075
    Platinum voltammetric disk electrode
    Transducers
    Platinum voltammetric electrode. 3 mm OD, PEEK body. 1 mm diameter disk,
  • ET075-3
    Pack of 3: Platinum voltammetric disk electrode
    Transducers
    Pack of 3: Platinum voltammetric disk electrode
  • ET076
    Gold voltammetric disk electrode
    Transducers
    Gold voltammetric electrode. 3 mm OD, PEEK body. 1 mm diameter disk,
  • ET076-3
    Pack of 3: Gold voltammetric disk electrode
    Transducers
    None
  • ET077
    Pack of 40.;ZENSOR TE100 Screen Printed Voltammetric Electrodes
    Transducers
    Zensor TE100 screen printed electrodes. 3 mm carbon disk electrode, with outer annular crescent carbon auxiliary electrode, and Ag/AgCl pellet reference electrode. Pack of 40.
  • ET078
    Pt/Ti Titanium wire anode ET078
    Transducers
    Pt-coated Titanium Auxiliary Electrode, 1.6 mm OD, length 70 mm, platinum coating 2.5 micron thick.
  • ET078-3
    Pack of 3: Pt-coated titanium wire electrode, 70 mm
    Transducers
    Pt-coated titanium wire Electrode, 1.6 mm OD, length 70 mm, platinum coating 2.5 micron thick.
  • ET079
    Copper disc Voltammetric electrode
    Transducers
    Copper voltammetric electrode. 3 mm OD, PEEK body. 1 mm diameter disk,
  • ET079-3
    Pack of 3: Copper voltammetric electrode
    Transducers
    None
  • ET080-12
    Electrochemical Reaction vessel, 3 mL, set of 12
    Accessories
    Set of 12 Electrochemical Reaction Vessels. supplied with open screw caps and silicone rubber lined gasket.
  • ET081-6
    Set of six Magnetic spin vanes for ET080
    Accessories
    None
  • ET082-6
    Pack of 6: PTFE Drilled Gaskets for ET080
    Transducers
    None
  • ET083
    ZENSOR SE100 Screen Printed Voltammetric Electrodes
    Transducers
    Zensor SE100 screen printed electrodes. 5 mm carbon disk electrode. Use with separate, conventional reference and auxiliary electrodes. Pack of 40.
  • ET084
    Mini Cell with Agitator
    Accessories
    Small glass jar (Wheaton W986297NG) and plastic stirrers 2 used in each ET014 set.
  • ET085
    Laboratory Arm for 12mm electrodes
    Accessories
    Desktop arm mount For 12mm electrodes.
  • ET086
    Pt/Ti Titanium wire anode 150mm long
    Transducers
    Pt-coated Titanium Auxiliary Electrode, 1.6 mm OD, length 150 mm, platinum coating 2.5 micron thick.
  • ET086-3
    Pack of 3: Pt-coated titanium wire electrode 150mm long
    Transducers
    None
  • ET087
    Nickel voltammetric disk electrode
    Transducers
    Nickel voltammetric electrode. 3 mm OD, PEEK body. 1 mm diameter disk,
  • ET087-1
    Nickel Disk Electrode
    Transducers
    Nickel voltammetric electrode. 3 mm OD, PEEK body. 1 mm diameter disk,
  • ET087-3
    Nickel Disk Electrode, Three pack.
    Transducers
    Nickel voltammetric electrode. 3 mm OD, PEEK body. 1 mm diameter disk,
  • ET088-1
    Silver disk electrode
    Transducers
    Silver voltammetric electrode. 3 mm OD- PEEK body. 1 mm diameter disk-
  • ET088-3
    Silver disk electrode. Three pack
    Transducers
    Silver voltammetric electrode. 3 mm OD- PEEK body. 1 mm diameter disk- Pack of 3
  • ET090-40
    Pack of 40: Kanichi Carbon Screen Printed Electrodes
    Transducers
    This SPE (Kanichi Carbon Screen Printed Electrodes) features a graphitic carbon working electrode, along with a carbon auxiliary electrode and Ag/AgCl reference. * Dimensions: 10 x 40 mm * Working electrode: 3 mm diameter disk, particulate graphitic carbon * Reference electrode: Ag/Agcl * Auxiliary electrode: particulate graphitic carbon. Supplied as a Pack of 40:
  • ET096
    Mini-Hydrogen electrode
    Transducers
    ET096 is a Mini-Hydrogen electrode. The hydrogen source must be replaced after 12 month. The head is made from PP and the shaft from PEEK the diameter of the shaft is just 1.6 mm. The head has a G 1/8'' BSP thread but it can also be used without being screwed in.The length of the shaft can be customized at additional cost. The connector lead is the same as used for the standard HydroFlex electrode (ET070) . It does not have a cartridge but a hydrogen generating button cell that lasts 12 months. Electrode has oring incl The material is FKM, the size 5.5mm ID diameter 1,2mm thickness.
  • ET097
    Replacement Hydrogen source for Mini-Hydrogen electrode ET096
    Transducers
    Replacement Hydrogen source/button cell for Mini-Hydrogen electrode ET096. The hydrogen source must be replaced after 12 months
  • ET098
    BVT Electrode Adapter
    Transducers
    BVT Electrode Adapter.This includes a PBA and and top and bottom cover2 o-rings and a data/instruction sheet
  • ET099
    Kanichi Electrode Adapter
    Accessories
    Kanichi electrode adapter accepts eDAQ Kanichi electrodes (ET090, ET091, ET092, ET093, ET094, ET095) for mounting in ET080 reaction vessels (also ET014). Sockets for 2 mm pin, and studs for alligator clip connection are provided which are suitable for the electrode leads of all eDAQ Potentiostats.
  • ET1010
    Piezo-electric Pulse Transducer
    Transducers
    A small, rugged piezo electric vibration/acceleration transducer. The unit plugs directly into an e-corder input. It is not intended for quantitative acceleration measurements.
  • ET1115
    Galvanic Oxygen Electrode
    Transducers
    Rugged, plastic body galvanic dissolved oxygen sensor. Response time 98% of final signal within 60 s. Temp range 0-50 C, output 35 mV Ă_x0082_Âą10 mV, 10-15Ă_x0082_ÂľA. The output, in air-saturated deionised water, is usually between 20-35 mV at 25 C with oxygen consumption on 3.45 x 10-13 Mole O2/s per mV of signal. Connects directly to a BNC input of an e-corder unit.
  • ET1120
    Micro-Oxygen Electrode (includes ET1121 Membrane Housing Kit)
    Transducers
    Micro-oxygen Electrode features low oxygen consumption- fast response (<20s) and requires less than a drop of liquid. Requires a EP354 isoPod to connect to an e-corder. Each electrode is supplied with an ET1121 Membrane Housing Kit consisting of six membranes- a bottle of electrolyte solution and a bulb pipette.
  • ET1121
    Replacement Membrane Housing Kit (for ET1120)
    Transducers
    Replacement Membrane Housing Kit (for ET1120).
  • ET117
    Membrane cap Kit for DO ET1117
    Transducers
    Pack of two replacement Membrane for ET1117 DO probe
  • ET118
    Micro universal stirrer.
    Accessories
    Micro universal stirrer for ET1117 or similar sized probe
  • ET120
    C4D Head for C4D CE System
    Transducers
    C4D Head Stage for 360 Âľm OD capillary electrophoresis (CE) tubing. software selectable gains of x1 and x5 and rectifier. Connects to all eDAQ C4D amplifiers and systems.
  • ET121
    Microchip Platform with C4D Electrodes
    Transducers
    This unit consists of a mechanical adapter to position a Microchip CE channel to allow C4D measurements. This platform connects to all C4D amplifiers and systems. This configuration is optimized for use with MicroChips having a 100Âľm bottom cover plate thickness. This platform contains the detection electrodes, excitation source , x1, x5 software selectable gain, ET195-2 Microfluidic Chips
  • ET121-Lemo10
    ET121 C4D Microfluidic Platform with POD to Lemo 10 Way cable
    Transducers
    This unit consists of a mechanical adapter to position a Microchip CE channel to allow C4D measurements. This platform connects to all C4D amplifiers and systems. This configuration is optimized for use with MicroChips having a 100Âľm bottom cover plate thickness. This platform contains the detection electrodes, excitation source , x1, x5 software selectable gain. This line item uses Cable, POD to Lemo 10 Way, EAID-00489-cab, instead of EAID-00019-cab
  • ET125
    General Purpose C4D head
    Transducers
    C4D Head stage suitable for contactless conductivity detection for 1/16 inch tubing. The head stage contains the excitation and detection circuits with x1, x5 software selectable gain and signal detection. Electrode separation is 9 mm
  • ET128
    Octal C4D head
    Transducers
    C4D Head stage suitable for contactless conductivity detection for 1/16 inch tubing. The head stage contains the excitation and detection circuits with x1, x5 software selectable gain and signal detection. Electrode separation is 9 mm
  • ET130
    IC/HPLC C4D head
    Transducers
    C4D Head stage suitable for contactless conductivity detection for 1/16 inch tubing. The head stage contains the excitation and detection circuits with x1, x5 software selectable gain and signal detection. Electrode
  • ET131
    Configurable General Purpose C4D head
    Transducers
    C4D Head stage suitable for contactless conductivity detection for 1/16in,1/32in & 380 micron tubing. The head stage contains the excitation and detection circuits with x1, x5 software, selectable gain and signal detection. Electrode separation is 4-9 mm
  • ET1400
    T-Type Thermocouple Probe - miniature.
    Transducers
    Miniature, precision T-Type thermocouple probe for liquids, gases and semisolids. Plastic handle with straight 75 mm stainless shaft, 1.5 mm diameter. Maximum temperature: 400degC, Time constant 0.5 secs, lead length: 1.5m. Suitable for use with EP356/EPU356 isoPod.
  • ET145-4
    Microchip , Pack of 4, 45mm
    Accessories
    45mm Micronit microfluidic chip with C4D electrodes, model number 35100C4D. Pack of four. Can be used with ET225 chip holder, ER230 HV Sequencer, and any eDAQ C4D Amp/detector.
  • ET16
    Electrode simulator
    Transducers
    The ET16 is a 6 way switched resistor network that simulates a range of electrochemical electrodes ranging in currents from 10mA to 100pA full scale. It provides a simple means of testing the operation of Potentiostats, Quadstat systems and isoPods.This electrode simulator is intended to be used to test Potentiostats and QuadStats.
  • ET1600
    pH micro Electrode - 1.6mm OD, 50mm tip length
    Transducers
    A miniature combination pH electrode suitable for use in a capillary flow through systems. Available in 1600Âľ tip diameter and body lengths of 20 mm. Active tip is less than 1 mm long. A Reference electrode is not required. Suitable for use with EPU353, EPU452 and EU168 isoPods. Other tip diameters(650u, 1000u) and lenghts (50, 75mm) are available on special order. Potential shifting device available. PSD not required with isoPods
  • ET1601
    MINI Ion Selective Electrode (Ca2+) Calcium
    Transducers
    2.5mm Half-cell MINI Electrode-(Ca2+) Calcium, Length 45 mm, work with Cable: BNC to crocodile/alligator clips, line item EC08
  • ET1602
    MINI Ion Selective Electrode (Cl-) Chloride
    Transducers
    2.5mm Half-cell MINI Electrode-(Cl-) Chloride, Length 45 mm, work with Cable: BNC to crocodile/alligator clips, line item EC08
  • ET1603
    MINI Ion Selective Electrode (Cu2+) Copper
    Transducers
    2.5mm Half-cell MINI Electrode-(Cu2+) Copper, Length 45 mm, work with Cable: BNC to crocodile/alligator clips, line item EC08
  • ET1604
    Nano Ion Selective Electrode for Fluoride (F-)
    Transducers
    Nano Ion Selective Electrode for Fluoride (F-), Length 45 mm, work with Cable: BNC to crocodile/alligator clips, line item EC008 SKU: M019
  • ET1605
    MINI Ion Selective Electrode (K+) Potassium
    Transducers
    2.5mm Half-cell MINI Electrode-(K+) Potassium, Length 45 mm, work with Cable: BNC to crocodile/alligator clips, line item EC08
  • ET1606
    Nano Ion Selective Electrode (Li+) Lithium
    Transducers
    2.5mm Half-cell MINI Electrode-(Li+) Lithium, Length 45 mm, work with Cable: BNC to crocodile/alligator clips, line item EC08
  • ET1607
    MINI Ion Selective Electrode (Mg2+) Magnesium
    Transducers
    2.5mm Half-cell MINI Electrode-(Mg2+) Magnesium, Length 45 mm, work with Cable: BNC to crocodile/alligator clips, line item EC08
  • ET1608
    MINI Ion Selective Electrode (Na+) Sodium
    Transducers
    2.5mm Half-cell MINI Electrode-(Na+) Sodium, Length 45 mm, work with Cable: BNC to crocodile/alligator clips, line item EC08
  • ET1609
    Nano Ion Selective Electrode for Ammonium (NH4+)
    Transducers
    Nano Ion Selective Electrode for Ammonium (NH4+), Length 45 mm, work with Cable: BNC to crocodile/alligator clips, line item EC08
  • ET1610
    MINI Ion Selective Electrode (NO2-) Nitrite
    Transducers
    2.5mm Half-cell MINI Electrode-(NO2-) Nitrite, Length 45 mm, work with Cable: BNC to crocodile/alligator clips, line item EC08
  • ET1611
    MINI Ion Selective Electrode (NO3-) Nitrate
    Transducers
    2.5mm Half-cell MINI Electrode-(NO3-) Nitrate, Length 45 mm, work with Cable: BNC to crocodile/alligator clips, line item EC08
  • ET1612
    MINI Ion Selective Electrode pH (CNT_ISE)
    Transducers
    2.5mm Half-cell MINI Electrode-pH (CNT_ISE), Length 45 mm, work with Cable: BNC to crocodile/alligator clips, line item EC08
  • ET1613
    MINI Ion Selective Electrode Reference
    Transducers
    2.5mm Half-cell MINI Electrode-Reference, Length 45 mm, work with Cable: BNC to crocodile/alligator clips, line item EC08
  • ET1614
    MINI Ion Selective Electrode (ClO4-) Perchlorate
    Transducers
    2.5mm Half-cell MINI Electrode-(ClO4-) Perchlorate, Length 45 mm, work with Cable: BNC to crocodile/alligator clips, line item EC08
  • ET1615
    MODULAR Ion Selective Electrode (Ca2+) Calcium, work with Single/Multi Probe
    Transducers
    4.6 mm Half-cell MODULAR Electrode-(Ca2+) Calcium, Length 50 mm, work with Single/Multi Probe, line item ET1632/ET1633
  • ET1616
    MODULAR Ion Selective Electrode (Cl-) Chloride, work with Single/Multi Probe
    Transducers
    4.6 mm Half-cell MODULAR Electrode-(Cl-) Chloride, Length 50 mm, work with Single/Multi Probe, line item ET1632/ET1633
  • ET1617
    MODULAR Ion Selective Electrode (Cu2+) Copper, work with Single/Multi Probe
    Transducers
    4.6 mm Half-cell MODULAR Electrode-(Cu2+) Copper, Length 50 mm, work with Single/Multi Probe, line item ET1632/ET1633
  • ET1618
    MODULAR Ion Selective Electrode (F-) Fluoride, work with Single/Multi Probe
    Transducers
    4.6 mm Half-cell MODULAR Electrode-(F-) Fluoride, Length 50 mm, work with Single/Multi Probe, line item ET1632/ET1633
  • ET1619
    MODULAR Ion Selective Electrode (K+) Potassium, work with Single/Multi Probe
    Transducers
    4.6 mm Half-cell MODULAR Electrode-(K+) Potassium, Length 50 mm, work with Single/Multi Probe, line item ET1632/ET1633
  • ET1620
    MODULAR Ion Selective Electrode (Li+) Lithium, work with Single/Multi Probe
    Transducers
    4.6 mm Half-cell MODULAR Electrode-(Li+) Lithium, Length 50 mm, work with Single/Multi Probe, line item ET1632/ET1633
  • ET1621
    MODULAR Ion Selective Electrode (Mg2+) Magnesium, work with Single/Multi Probe
    Transducers
    4.6 mm Half-cell MODULAR Electrode-(Mg2+) Magnesium, Length 50 mm, work with Single/Multi Probe, line item ET1632/ET1633
  • ET1622
    MODULAR Ion Selective Electrode (Na+) Sodium, work with Single/Multi Probe
    Transducers
    4.6 mm Half-cell MODULAR Electrode-(Na+) Sodium, Length 50 mm, work with Single/Multi Probe, line item ET1632/ET1633
  • ET1623
    MODULAR Ion Selective Electrode (NH4+) Ammonium, work with Single/Multi Probe
    Transducers
    4.6 mm Half-cell MODULAR Electrode-(NH4+) Ammonium, Length 50 mm, work with Single/Multi Probe, line item ET1632/ET1633
  • ET1624
    MODULAR Ion Selective Electrode (NO2-) Nitrite, work with Single/Multi Probe
    Transducers
    4.6 mm Half-cell MODULAR Electrode-(NO2-) Nitrite, Length 50 mm, work with Single/Multi Probe, line item ET1632/ET1633
  • ET1625
    MODULAR Ion Selective Electrode (NO3-) Nitrate, work with Single/Multi Probe
    Transducers
    4.6 mm Half-cell MODULAR Electrode-(NO3-) Nitrate, Length 50 mm, work with Single/Multi Probe, line item ET1632/ET1633
  • ET1626
    MODULAR Ion Selective Electrode pH (CNT_ISE), work with Single/Multi Probe
    Transducers
    4.6 mm Half-cell MODULAR Electrode-pH (CNT_ISE), Length 50 mm, work with Single/Multi Probe, line item ET1632/ET1633
  • ET1627
    MODULAR Ion Selective Electrode Reference, work with Single/Multi Probe
    Transducers
    4.6 mm Half-cell MODULAR Electrode-Reference, Length 50 mm, work with Single/Multi Probe, line item ET1632/ET1633
  • ET1628
    MODULAR Ion Selective Electrode (ClO4-) Perchlorate, work with Single/Multi Probe
    Transducers
    4.6 mm Half-cell MODULAR Electrode-(ClO4-) Perchlorate, Length 50 mm, work with Single/Multi Probe, line item ET1632/ET1633
  • ET1629
    MODULAR Ion Selective Electrode (Ag+) Silver, work with Single/Multi Probe
    Transducers
    4.6 mm Half-cell MODULAR Electrode-(Ag+) Silver, Length 50 mm, work with Single/Multi Probe, line item ET1632/ET1633
  • ET1630
    MODULAR Ion Selective Electrode (Br-) Bromide, work with Single/Multi Probe
    Transducers
    4.6 mm Half-cell MODULAR Electrode-(Br-) Bromide, Length 50 mm, work with Single/Multi Probe, line item ET1632/ET1633
  • ET1631
    MODULAR Ion Selective Electrode (I-) Iodide, work with Single/Multi Probe
    Transducers
    0.0
  • ET1633
    Multi ION Probe for up to 7 Modular Electrodes
    Transducers
    25 mm Multi ION Probe for up to 7 Modular Electrodes.Customize your own probe, multiple electrodes in a small size handy probe. Diameter 25 mm, length 150 mm, Connector M12 / 7xBNC /Other, Cable 1m. Other terminations, available IONS:(NH4+) Ammonium(NO2-) Nitrite(NO3-) NitratepH (CNT_ISE)Reference Electrode(ClO4-) Perchlorate(Ag+) Silver(Br-) Bromide(I-) Iodide(Ca2+) Calcium(Cl-) Chloride(Cu2+) Copper(F-) Fluoride(K+) Potassium(Li+) Lithium(Mg2+) Magnesium(Na+) Sodium
  • ET1634
    Single Ion Probe with Mini Electrode inserted (Ca2+) Calcium
    Transducers
    Single Ion Probe with Mini Electrode inserted (Cl-) Chloride, Diameter 12 mm, Length 145 mm, Connector BNC, Cable 1m, 3m or 5m length; Use with Standard Ion/mV/pH ISO Pod.Works with a (Ca2+) Calcium Electrode MODULAR ION Electrode
  • ET1635
    Single Ion Probe with Mini Electrode inserted (Cl-) Chloride
    Transducers
    Single Ion Probe with Mini Electrode inserted (Cl-) Chloride, Diameter 12 mm, Length 145 mm, Connector BNC, Cable 1m, 3m or 5m length; Use with Standard Ion/mV/pH ISO Pod.Works with a (Cl-) Chloride Electrode MODULAR ION Electrode
  • ET1636
    Modular Single Ion Selective Electrode (Cu2+) Copper
    Transducers
    SINGLE ION with probe and MODULAR ION, Diameter 12 mm, Length 145 mm, Connector BNC, Cable 1m, 3m or 5m length; Use with Standard Ion/mV/pH ISO Pod.Works with a (Cu2+) Copper Electrode MODULAR ION Electrode
  • ET1637
    Single Ion Probe with Mini Electrode inserted (F-) Fluoride
    Transducers
    Single Ion Probe with Mini Electrode inserted (F-) Fluoride, Diameter 12 mm, Length 145 mm, Connector BNC, Cable 1m, 3m or 5m length; Use with Standard Ion/mV/pH ISO Pod.Works with a (F-) Fluoride Electrode MODULAR ION Electrode
  • ET1638
    Single Ion Probe with Mini Electrode inserted (K+) Potassium
    Transducers
    Single Ion Probe with Mini Electrode inserted (Cl-) Chloride, Diameter 12 mm, Length 145 mm, Connector BNC, Cable 1m, 3m or 5m length; Use with Standard Ion/mV/pH ISO Pod.Works with a (K+) Potassium Electrode MODULAR ION Electrode
  • ET1639
    Single Ion Probe with Mini Electrode inserted (Li+) Lithium
    Transducers
    Single Ion Probe with Mini Electrode inserted (Li+) Lithium, Diameter 12 mm, Length 145 mm, Connector BNC, Cable 1m, 3m or 5m length; Use with Standard Ion/mV/pH ISO Pod.Works with a (Li+) Lithium Electrode MODULAR ION Electrode
  • ET1640
    Single Ion Probe with Mini Electrode inserted (Mg2+) Magnesium
    Transducers
    Single Ion Probe with Mini Electrode inserted (Mg2+) Magnesium, Diameter 12 mm, Length 145 mm, Connector BNC, Cable 1m, 3m or 5m length; Use with Standard Ion/mV/pH ISO Pod.Works with a (Mg2+) Magnesium Electrode MODULAR ION Electrode
  • ET1641
    Single Ion Probe with Mini Electrode inserted (Na+) Sodium
    Transducers
    Single Ion Probe with Mini Electrode inserted (Na+) Sodium, Diameter 12 mm, Length 145 mm, Connector BNC, Cable 1m, 3m or 5m length; Use with Standard Ion/mV/pH ISO Pod.Works with a (Na+) Sodium Electrode MODULAR ION Electrode
  • ET1642
    Single Ion Probe with Mini Electrode inserted (NH4+) Ammonium
    Transducers
    Single Ion Probe with Mini Electrode inserted(NH4+) Ammonium, Diameter 12 mm, Length 145 mm, Connector BNC, Cable 1m, 3m or 5m length; Use with Standard Ion/mV/pH ISO Pod.Works with a (NH4+) Ammonium Electrode MODULAR ION Electrode
  • ET1643
    Single Ion Probe with Mini Electrode inserted (NO2-) Nitrite
    Transducers
    Single Ion Probe with Mini Electrode inserted (NO2-) Nitrite, Diameter 12 mm, Length 145 mm, Connector BNC, Cable 1m, 3m or 5m length; Use with Standard Ion/mV/pH ISO Pod.Works with a (NO2-) Nitrite Electrode MODULAR ION Electrode
  • ET1644
    Single Ion Probe with Mini Electrode inserted (NO3-) Nitrate
    Transducers
    Single Ion Probe with Mini Electrode inserted (NO3-) Nitrate, Diameter 12 mm, Length 145 mm, Connector BNC, Cable 1m, 3m or 5m length; Use with Standard Ion/mV/pH ISO Pod.Works with a (NO3-) Nitrate Electrode MODULAR ION Electrode
  • ET1645
    Half-cell Ion Selective Electrode for pH incl probe(CNT_ISE)
    Transducers
    SINGLE ION with probe and MODULAR ION, Diameter 12 mm, Length 145 mm, Connector BNC, Cable 1m, 3m or 5m length; Use with Standard Ion/mV/pH ISO Pod.Works with a pH (CNT_ISE) Electrode MODULAR ION Electrode
  • ET1646
    Single Ion Probe with Mini Reference Electrode inserted
    Transducers
    Single Ion Probe with Mini Reference Electrode inserted, Diameter 12 mm, Length 145 mm, Connector BNC, Cable 1m, 3m or 5m length; Use with Standard Ion/mV/pH ISO Pod.Works with a Reference Electrode MODULAR ION Electrode
  • ET1647
    Single Ion Probe with Mini Electrode inserted (ClO4-) Perchlorate
    Transducers
    Single Ion Probe with Mini Electrode inserted (Br-) Bromide, Diameter 12 mm, Length 145 mm, Connector BNC, Cable 1m, 3m or 5m length; Use with Standard Ion/mV/pH ISO Pod.Works with a (ClO4-) Perchlorate Electrode MODULAR ION Electrode
  • ET1648
    Modular Single Ion Selective Electrode (Ag+) Silver
    Transducers
    SINGLE ION with probe and MODULAR ION, Diameter 12 mm, Length 145 mm, Connector BNC, Cable 1m, 3m or 5m length; Use with Standard Ion/mV/pH ISO Pod.Works with a (Ag+) Silver Electrode MODULAR ION Electrode
  • ET1649
    Single Ion Probe with Mini Electrode inserted (Br-) Bromide
    Transducers
    Single Ion Probe with Mini Electrode inserted (Br-) Bromide, Diameter 12 mm, Length 145 mm, Connector BNC, Cable 1m, 3m or 5m length; Use with Standard Ion/mV/pH ISO Pod.Works with a (Br-) Bromide Electrode MODULAR ION Electrode
  • ET1650
    Single Ion Probe with Mini Electrode inserted (I-) Iodide
    Transducers
    Single Ion Probe with Mini Electrode inserted (I-) Iodide, Diameter 12 mm, Length 145 mm, Connector BNC, Cable 1m, 3m or 5m length; Use with Standard Ion/mV/pH ISO Pod.Works with a (I-) Iodide Electrode MODULAR ION Electrode
  • ET190-2
    Microchip , Pack of 2, 90mm
    Accessories
    90mm Micronit microfluidic chip with C4D electrodes, model number T85100C4D. Pack of two. Can be used with ET225 chip holder, ER430 HV Sequencer, and any eDAQ C4D Amp/detector.
  • ET195-2
    Microchip , Pack of 2, 90mm
    Interface and Third Party Prod
    This line item contains QTY 2 units Cross-shaped channel chip- platform IFludic interface: Luer Channel width: 75 Âľm / Channel depth: 75Âľm / Channel length: 87.0 mmHole Diameter: 1.0 mm / Material: Zeonor /Lid thickness: 100 Âľm
  • ET225
    MCE Adapter
    Transducers
    ET225 is microfluidic chip adapter specially configured to hold Micronit 45 (or 90 mm) microfluidic chips together will all necessary HV connections. The C4D circuit board is an integral part of this adapter and connects directly to the any eDAQ C4D system. Interlocks are provided to allow safe operation of the system in the presence of internal High voltages.
  • ET226
    Drop Counter
    Transducers
    Drop counter for student titrations uses a pulsed infrared light source and reflective detector to produce an electrical pulse (5 V resting to 0 V pulse) every time a drop passes. Connects to e-corder Pod port. Used with Chart software which counts the pulses and converts the cumulative count to a volume measurement. Commonly used with a pH or Conductivity isoPod, for titration experiments.
  • ET325-5
    Thin film solar cell, 3V, 25 mA (five pack)
    Accessories
    A five pack of flexible thin film, amorphous silicon, solar cells that are ideal for teaching the principles of solar energy collection. Use with a potentiostat system to: determine the open circuit potential (maximum voltage, Vmax); determine short circuit current (maximum current, imax); ramp the potential from zero to Vmax and prepare a graph of i vs V multiply the iV and V signals to get the work signal; and then repeat at different illumination levels. Electrical: 3 V, 25 mA. Dimensions w x h: 25 x 114 mm
  • ET405
    K-type Temperature Probe
    Transducers
    Hand held tubular stainless steel K thermocouple temperature probe suitable for use in fluids in the temperature range of -25Ă_x0082_ÂĄC to 200 Ă_x0082_ÂĄC. Fitted with 2 pin mini K thermocouple connector to suit EP356/EPU356 Thermocouple isoPod.
  • ET5733
    Combination pH Electrode
    Transducers
    Combination pH electrode is suitable for operation from 0-60 deg C, 0-14 pH. Cleanliness of the sensor and junction is critical for accurate measurement. These features make this electrode an excellent alternative to conventional pH electrodes where there is a risk of bulb breakage, such as during laboratory classes. Requires an EP353/EPU356 pH isoPod.
  • ET901
    Conductivity Cell, k=0.1, 12 mm diameter glass body
    Transducers
    Conductivity Cell, k=0.1, 12 mm diameter, 120 mm long, glass body, fitted with 1 m cable with BNC termination. Use with low conductivity solutions (<0.1 mS/cm). Suitable for use with a EP357/EPU35 Conductivity isoPod.
  • ET902
    Conductivity Cell, k=1, 12 mm diameter glass body
    Transducers
    Conductivity Cell, k=1, 12 mm diameter, 120 mm long, glass body, fitted with 1 m cable with BNC termination. Use with solutions up to 100 mS/cm. Suitable for use with a EP357/EPU35 Conductivity isoPod.
  • ET903
    Conductivity Cell, k=10, 12 mm diameter glass body
    Transducers
    Conductivity Cell, k=10, 12 mm diameter, 120 mm long, glass body, fitted with 1 m cable with BNC termination. Use with high conductivity solutions (>100 mS/cm). Suitable for use with a EP357/EPU35 Conductivity isoPod.
  • ET908
    Flow-Thru Conductivity Electrode. k=1. Fits 1/8" ID tubing.
    Transducers
    Flow through Conductivity Electrode, 4.3 cm long, 1m lead, 8 mm body, cell volume 0.093 ml, cell constant approximatly x1, T fitting 1/8" (3.2 mm ID tubing), material ABS. Suitable for use with a EP357/EPU35 Conductivity isoPod. Also 16-900 for 1/16" tubing
  • ET915
    Dip-In Conductivity Electrode. k=1. Body is 3.2 mm diameter.
    Transducers
    Conductivity electrode for immersion, 14.6 cm long, lead length 1m, 3.2 mm body, cell constant approximatly x1, immersion depth 5 mm. Construction ABS. Suitable for use with a EP357/EPU357 Conductivity isoPod.
  • ET916
    Flow-Thru Conductivity Electrode. k=1. Fits 1/16" ID tubing.
    Transducers
    Flow through conductivity electrode, 4.2 cm long, lead length 1m, 6.4 mm body, cell volume 0.017 ml, cell constant approx. 1, T fitting 1/16" (1.6 mm ID tubing), material ABS. Suitable for use with a EP357/EPU357 Conductivity isoPod.
  • EU168
    Quad isolated pH/ISE pod
    USB isoPods
    The EU168 provides 4 group isolated amplifiers capable of measuring pH, ISE and +/-2000mV, The unit is powered and communicates directly via the USB bus. 20 - 24 bit ADC precision and 0.1 accuracy is provided. A range of software tools are provided including serial commands. This unit was specifically developed for TECAN.
  • FARAD2
    Faraday Cage
    Accessories
    The faraday case, Farad2, is an essential item for electroanalytical experiments. It is well designed to block out external EMI noise and firmly enclosure all the components of electrochemical cell (electrodes, vials, etc.). The spacious interior allows you to set up electronic components or systems easily.
  • SDx-A1
    tethaPlate Assembly Jig
    SDx Products
    This press clamps the white polycarbonate 6-chamber tethaPlate cartridge to the transparent polycarbonate slide (on which the 6 tether-plated god gold working electrodes electrodes are located) during the adhesion step.The final tethaPlate assemby is now ready for phospholipid membrane creation and ion channel insertion for measurements with a tethaPod or tethaPatch experiment.SpecificationsVolume: 1 mLTotal lipid concentration: 3 mM in ethanolLipid mixture: diphytanyletherphosphatidylcholine 70%, and glycerodiphytanylether 30%Long term storage: 4Ă_x0082_°CUsage: 0 45Ă_x0082_°C
  • SDx-A2
    tethaPod Test Card
    SDx Products
    The SDx tethaPod Test Card provides standard rerstance and capacitance values to each of the six channels of the tehaPod. It is used to ensure that all tethaPod or tethPatch channels are working correcty. It is positioned in place of the standard tethaPlate modules. Specifications Membrane resistance, Rm: 1 MohmMembrance Capacitance, Cm: 10 nFSeries Capacitance, Cs: 100 nF
  • SDx-APP2
    tethaQuick Software
    SDx Products
    tethaQuick SoftwareThis software is for tethaPod units built May 2015 or later
  • SDx-BG
    SDx-BG
    SDx Products
    a bare gold electrode thethaPlate. tethaPlate - 10 pack Long term storage: 4Ă_x0082_°C Usage: 0-45 deg C
  • SDx-MK1
    SDx Mega Kit
    SDx Products
    This kit enables both continous membrane conductance monitoring, and voltage clamp style experiments on tethered membrane systems and comprises: SDx-R5 tethaPod Starter Kit, SDx-R2 tethaPatch unit, ER466 Integrated Potentiostat System and ES260 EChem software
  • SDx-R1
    tethaPod
    SDx Products
    SDX tethaPod Plate Reader with USB interface
  • SDx-R2
    TethaPatch
    SDx Products
    SDXTethaPatch Multiplexer
  • SDx-R5
    tethaPod start-up kit
    SDx Products
    tethaPod Starter kit comprising: 1 x SDx-R1 tethaPod 1 x SDx-A2 Test Card 10 x SDx-T10 tethaPlate assembly 1 x SDx-S1 Lecond Layer lipids 1 x SDx-A1 Clamp and slide assembly jig
  • SDx-S1
    Phospholipid mix
    SDx Products
    A 1 mL vial containing a ethanolic solution of lipids suitable for phospholipid bilayer membrane formation when used with a tethaPlate. SpecificationsVolume: 1 mLTotal lipid concentration: 3 mM in ethanolLipid mixture: diphytanyletherphosphatidylcholine 70%, and glycerodiphytanylether 30%Long term storage: 4Ă_x0082_°CUsage: 0 45Ă_x0082_°C
  • SDx-T10
    tethaPlate - 10 pack
    SDx Products
    The tethaPlate is a 6-chamber sample holder for tethered membrane preparations. It is used in conjunction with a tethaPod or tethaPatch system for the determination of membrane conduction and studies of protein ion channels. The working electrodes are pre-coated with tethering agent and the plate is ready for the addition of phospholipids for membrane creation. The tether/spacer ratio is normally set at 1:10. Other ratios can be supplied on special order. The tethaPlate is delivered in two sections which are assembled with the aid of an Assembly Jig. Sample chambers. Tethers: benzyl-disulphide-bis-tetraethyleneglycolmonophytane. Spacers: benzyl-disulphide-bis-tetraethyleneglycolTether/Spacer ratio: 1/10. Long term storage: 4Ă_x0082_°C Usage: 0-45 deg C
  • SDx-T10-5
    tethaPlate -5 pack
    SDx Products
    The tethaPlate is a 6-chamber sample holder for tethered membrane preparations. It is used in conjunction with a tethaPod or tethaPatch system for the determination of membrane conduction and studies of protein ion channels. The working electrodes are pre-coated with tethering agent and the plate is ready for the addition of phospholipids for membrane creation. The tether/spacer ratio is normally set at 1:10. Other ratios can be supplied on special order. The tethaPlate is delivered in two sections which are assembled with the aid of an Assembly Jig. Sample chambers. Tethers: benzyl-disulphide-bis-tetraethyleneglycolmonophytane. Spacers: benzyl-disulphide-bis-tetraethyleneglycolTether/Spacer ratio: 1/10. Long term storage: 4 Ă_x0082_°C Usage: 0-45 deg C
  • SP100
    SP1 Electrochemical Workstation.
    Instruments
    SP1 Electrochemical Workstation. 1MHz, 1 Amp,10Volt compliance Includes following software modules: Energy(Battery) test software package BATe EIS software package EISe Electrochemical analysis software package EASe Corrosion test software package CORe
  • SP200
    SP2 Electrochemical Workstation. 1MHz, 2 Amp, 10Volt compliance
    Instruments
    SP2 Electrochemical Workstation. 1MHz, 2 Amp/10Volt compliance. Includes folloing softwre modules: Energy(Battery) test software package BATe EIS software package EISe Electrochemical analysis software package EASe Corrosion test software package CORe

Kiválasztott Termékek:

    Bevásárló kosár

    0
    image/svg+xml

    Nem található termék a kosárban.

    Vásárlás folytatása

    FIGYELMEZTETÉS

    Tisztelt Felhasználó!

    Ön magánszemélyként kíván regisztrálni. Erre természetesen van lehetősége, azonban felhívjuk figyelmét, hogy a magánszemélyként leadott megrendeléseket kollégáink átnézik a teljesítés előtt.

    A vonatkozó törvényi előírások értelmében nem minden termékünk értékesíthető magánszemélyek részére.

    Megértését köszönjük!